Operating instructions
TD 92579GB
2009-04-15/ Ver. B
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 3.0.x)
70
3 Enter the Message Center Number in the Fix Message Center No. field.
The MWI enabled check box is only relevant if the field above is left blank. In this
case select the MWI enabled check box to send a notification to your own number
instead of the Message Center Number.
Note: For some IP-PBXs no configuration is necessary for this service.
4 Enter the number of the message center in the Local Clear of MWI field to clear the
message waiting indication locally when dialling the number.
5 Click "OK".
6 Reset in order to make the changes take effect, see 8.16 Reset on page 113.
Figure 42.
Figure 31. Supplementary services
8.5.12 Select Mode
1 Select DECT > Master.
2 Select in the Mode drop-down list:
• "Active", if this IPBS/IPBL is the Master.
• "Standby", if this IPBS/IPBL is the Standby Master.
• "Deployment" is used only for coverage test. The speech from the handset is
looped back to the handset.
Call Completion Busy Subscriber Notifies the caller when a busy number
becomes available and reinitiates the call
Only works on H.323
Logout User Logs out the user and the Portable Device
becomes anonymously subscribed.
Clear Local Settings Clears all locally stored feature settings
and all features are deactivated
Feature Description