Operating instructions

TD 92579GB
2009-04-15/ Ver. B
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 3.0.x)
65
1 In Windows, select "Run..." in the Start menu.
2 Enter "regedit" and click "OK" to start the Windows Registry Editor.
3 In the Editor go to the
"HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\NTDS\Parameters\
LDAPServerIntegrity" key.
4 Click on the key with the right mouse button and click "Modify".
5 Change the key value of 2 to the value of 1.
6 Click "OK".
8.4.4 Check LDAP Replicator Status
1 Select LDAP > Replicator-Status.
The following information can be checked:
Server - The IP address and port of the LDAP server.
Active Directory Replication - Current state of replication. Four states are
possible: Stopped, Starting, Up, Down
remote - State of replication in the source directory. Three states are possible:
Stopped, Active, Completed
notify - Number of change notifications received from the server
paged - Number of objects received from AD server in response to paged search
requests
no match - Number of objects received that are not matching the configured
LDAP filter condition
discarded - Number of objects discarded because no suitable map is found
local - State of replication in the destination directory. Three states are possible:
Stopped, Active, Completed
notify - Number of change notifications sent to the server
add - Number of locally added objects
del - Number of locally deleted objects
modify - Number of locally modified objects
pending - Number of local objects waiting to be sent to the server
8.4.5 Expert tool
The Expert function should only be used after consultation with Ascom Technical Support.