Operating instructions
TD 92579GB
2009-04-15/ Ver. B
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 3.0.x)
126
Appendix B: RFP Power Consumption
The tables below show power consumption for a base station connected to the IPBL. The
power consumption of the IPBL is approximately 15 W.
Note: The maximum cable length for base stations connected to the IPBL must not
exceed 1500 meters.
B.1 KRCNB 201/DCT1800
Figure 3.
Table 1 Power consumption (watts) of base stations and cabling when powered with 48 V
Cable
length
(metres)
0.4 mm wire size (∅) 0.5 mm wire size (∅) 0.6 mm wire size (∅)
0 EPP 1 EPP 0 EPP 1 EPP 0 EPP 1 EPP
0 7.5 7.5 7.5 7.5 7.5 7.5
100 7.9 7.8 7.8 7.7 7.7 7.6
200 8.3 8.0 8.0 7.8 7.8 7.7
300 8.9 8.3 8.3 8.0 8.0 7.8
400 9.8 8.7 8.7 8.2 8.2 7.9
500 11.3 9.2 9.2 8.5 8.4 8.0
600 - 9.8 9.8 8.7 8.6 8.2
700 - 10.7 10.7 9.0 8.8 8.3
800 - 12.3 12.3 9.4 9.1 8.4
900 - - - 9.8 9.5 8.6
1000 - - - 10.3 9.9 8.8
1100 - - - 11.1 10.4 8.9
1200 - - - 12.3 11.1 9.1
1300 - - - - 12.1 9.3
1400 - - - - - 9.6
1500 - - - - - 9.9
1600 - - - - - 10.2
1700 - - - - - 10.6
1800 - - - - - 11.1
1900 - - - - - 11.7
2000 - - - - - 12.7
2100 - - - - - -
2200 - - - - - -
2300 - - - - - -
2400 - - - - - -
2500 - - - - - -
2600 - - - - - -
2700 - - - - - -