10 Troubleshooting
10.1 Load Firmware Using the Gwload Tool
If the firmware is corrupt, for example if firmware download is interrupted the IPBS/IPBL
could become unreachable by the web GUI. It will not be possible to load new firmware or
to start correctly. If this occurs, the IPBS/IPBL runs on the bootcode and the Gwload tool (a
tftp-style client used to repair a broken firmware) can be used to upload firmware.
1 Download the Gwload software from the IP-DECT system provider.
2 Set the IPBS/IPBL in TFTP-mode by performing a medium (~3 sec) hardware reset,
see
8.17 Reset Using the Reset Button on page 113.
3 Start a command window.
To update with wew firmware, execute the following command from the folder
where the gwload.exe file is located:
IPBS:
gwload /setip /i <ipaddress> /gwtype 1201 /prot <..path/firmwarefilename> /go
IPBL:
gwload /setip /i <ipaddress> /gwtype 4001 /prot <..path/firmwarefilename> /go
4 If there is more than one IPBS/IPBL in TFTP mode, select the unit to update and press
enter.
10.2 Fault Code Descriptions
This section lists the possible fault codes and their descriptions.
Description Code Device
RFP disconnected 0x000e0001 IPBS/IPBL
RFP malfunctioning 0x000e0002 IPBS/IPBL
RFP disabled 0x000e0003 IPBS/IPBL
RFP software download failed 0x000e0004 IPBS/IPBL
High temperature 0x000f0001 IPBL
High power consumption 0x000f0002 IPBL
Supply voltage low 0x000f0004 IPBL
Supply voltage high 0x000f0008 IPBL
Fan failure 0x000f0010 IPBL
Synchronization ring broken 0x00100001 IPBL
Reference Synchronization Signal Lost 0x00100002 IPBL
Synchronization Lost 0x00100004 IPBL
RFP unsynchronized 0x000e0005 IPBS
Synchronization to alien system lost 0x000e0006 IPBS
Backup synchronization master active 0x000e0007 IPBS
Other DECT system with same sysid detected 0x000e0008 IPBS
Standby Master is active 0x00030001 IPBS/IPBL