Operating instructions
TD 92579GB
2009-04-15/ Ver. B
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 3.0.x)
105
5 Select DECT > Master.
6 Enter the IP address to the SIP proxy (registrar) in the Proxy text field.
7 Enter the IP address to the alternative SIP proxy (registrar) in the Alt. Proxy text field.
8 Select the Enbloc Dialing check box.
9 Select the Allow DTMF through RTP check box.
10 Select the Register with number check box.
If H.323 protocol is used:
11 Select DECT > Master
12 Enter the address to the gatekeeper in the Gatekeeper IP Address text field.
If the device is configured as a Standby Master:
13 Enter the address to the Master in the Primary Master IP Address text field.
14 Reset in order to make the changes take effect, see 8.16 Reset.
8.13.4 Downgrade from software version 3.x.x to 2.x.x
If a system with 3.x.x firmware and boot file is downgraded to a 2.x.x version, the HTTP
server part of the boot code is removed.
If the firmware is downgraded to version 2.x.x, the LDAP replication must be activated
again.
1 Select LDAP > Replicator.
2 Select the Enable check box to activate LDAP replication.