Installation and Operation Manual

Table Of Contents
TD 92579EN
10 April 2015 / Ver. N
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X)
92
Figure 12. The sync trees for region 0, 1 and 2 where region 0 is fully expanded.
Region Details
1 Select DECT Sync > Air Sync Overview.
2 Click on the region ID text at top above the sync tree.
3 If this has not already been done: In the Region Details window, enter a name for
the region.
4 In section Statistics, there are three counters:
- Calculations: Is incremented each time the sync tree is calculated.
- Configurations: Is incremented when an IPBS has received a new sync instruction.
- Sync Lost: Is incremented when an IPBS stops to handle radio traffic for a while
and after that restarts the synchronization procedure.
To clear the counters, click "Clear".
Reference Synchronization
To get the Sync Master to resynchronize to the reference sync, do as follows:
1 Select DECT Sync > Air Sync Overview.
2 Click on the region ID text at top above the sync tree.
3 In the Region Details window, click "Start". When resynchronizing, all ongoing calls
in the region will be disconnected.