Installation and Operation Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 IP Security
- 3 Configuration
- 3.1 Requirements
- 3.2 Access the GUI
- 3.3 GUI Web Access
- 3.4 Configure the Mobility Master
- 3.5 Configure the Standby Mobility Master
- 3.6 Configure the Pari Master
- 3.7 Configure the Standby Pari Master
- 3.8 Configure the Master
- 3.9 Configure the Standby Master
- 3.10 Plug and Play Configuration
- 3.11 Configure the Radio
- 3.12 Configure Deployment
- 3.13 Add Users
- 4 Operation
- 4.1.1 Name the IPBS and IPBL
- 4.1.2 Change User Name and Password
- 4.1.3 Centralized Management of Administrator and Auditor Accounts Using Kerberos
- 4.1.4 Configure the NTP Settings
- 4.1.5 Certificates
- 4.1.6 License
- 4.2.1 Set DHCP Mode
- 4.2.2 Set a Static IP Address
- 4.2.3 Dynamic IP address via DHCP
- 4.2.4 Link
- 4.2.5 Configure VLAN
- 4.2.6 View LAN Statistics
- 4.2.7 Enable RSTP (only for IPBL)
- 4.2.8 Deactivate LAN Port (only for IPBL)
- 4.3.1 Configure IP Settings
- 4.3.2 Routing
- 4.4.1 Configure LDAP Server
- 4.4.2 Check LDAP Server Status
- 4.4.3 Configure LDAP Replicator
- 4.4.4 Check LDAP Replicator Status
- 4.4.5 Expert tool
- 4.5.1 Change System Name and Password
- 4.5.2 Set Subscription Method
- 4.5.3 Configure Authentication Code
- 4.5.4 Select Tones
- 4.5.5 Set Default Language
- 4.5.6 Set Frequency Band
- 4.5.7 Enable Carriers
- 4.5.8 Local R-Key Handling
- 4.5.9 No Transfer on Hangup
- 4.5.10 No On-Hold Display
- 4.5.11 Display Original Called
- 4.5.12 Early Encryption
- 4.5.13 Configure Coder
- 4.5.14 Secure RTP
- 4.5.15 Configure Supplementary Services
- 4.5.16 Select Mode
- 4.5.17 Set Master Id
- 4.5.18 Enable PARI Function
- 4.5.19 Set Region Code
- 4.5.20 Configure Gatekeeper
- 4.5.21 Registration for Anonymous Devices
- 4.5.22 Conferencing Unit
- 4.5.23 Select Crypto Master Mode
- 4.5.24 Select Mobility Master Mode
- 4.5.25 Connect Mobility Master to other Mobility Master(s)
- 4.5.26 Disconnect Mobility Master from other Mobility Master(s)
- 4.5.27 Connect Mobility Master to a Crypto Master
- 4.5.28 Connect Master to a Mobility Master
- 4.5.29 Enable the Radio
- 4.5.30 Enter IP Address to the PARI Master and the Standby PARI Master
- 4.5.31 Multiple Radio Configuration
- 4.5.32 PARI
- 4.5.33 SARI
- 4.5.34 Configure Air Synchronization
- 4.6.1 Add instance id to the user registration with the IP-PBX
- 4.6.2 IP-PBX supports redirection of registration when registered to alternative proxy
- 4.6.3 Use local contact port as source port for TCP and TLS connections
- 4.6.4 Session Timer (initial value)
- 4.7.1 Configure Messaging
- 4.7.2 Device Management
- 4.7.3 Service Discovery
- 4.7.4 Send Status Log
- 4.7.5 Module Fault List
- 4.8.1 Configure Automatic Firmware Update
- 4.8.2 Configure Logging
- 4.8.3 Configure the HTTP settings
- 4.8.4 Configure the HTTP Client settings
- 4.8.5 SNMP
- 4.8.6 Phonebook
- 4.8.7 Configure IP-DECT to Connect to a Presence System Using ICP
- 4.9.1 Show all Registered Users in the IP-DECT System
- 4.9.2 Search for User Information
- 4.9.3 Add a User
- 4.9.4 Add a User Administrator
- 4.9.5 Export the Users to a csv file
- 4.9.6 Show Anonymous
- 4.10.1 Radios
- 4.10.2 RFPs
- 4.10.3 Sync Ring
- 4.10.4 Sync Ports
- 4.10.5 Air Sync
- 4.10.6 Sync Lost Counter in IPBS
- 4.11.1 Air Sync Overview
- 4.11.2 Disturbances
- 4.11.3 Status
- 4.12.1 Display All Ongoing Calls in the System
- 4.12.2 Display Calls
- 4.12.3 Handover
- 4.13.1 General
- 4.13.2 Interfaces
- 4.13.3 SIP Interfaces
- 4.13.4 Gatekeeper Interfaces
- 4.13.5 Routes – Configuration
- 4.13.6 Show Active Calls
- 4.15.1 Before Upgrading
- 4.15.2 Upgrading Sequence
- 4.15.3 Software Upgrade from 2.X.X
- 4.15.4 Software Upgrade
- 4.15.5 Configuration After Updating the Firmware From Software Version 2.X.X to Later
- 4.15.6 Configuration After Updating the Firmware From Software Version 3.X.X to Later
- 4.22.1 Update Configuration
- 4.22.2 Update Firmware
- 4.22.3 Update the Boot File
- 4.22.4 Update the RFPs
- 4.27.1 Logging
- 4.27.2 Tracing
- 4.27.3 Alarms
- 4.27.4 Events
- 4.27.5 Performance
- 4.27.6 Config Show
- 4.27.7 Ping
- 4.27.8 Traceroute
- 4.27.9 Environment
- 4.27.10 RFP Scan
- 4.27.11 Service Report
- 4.28.1 Idle Reset
- 4.28.2 Immediate Reset
- 4.28.3 TFTP Mode
- 4.28.4 Boot
- 5 Commissioning
- 6 Troubleshooting
- 7 Related Documents
- Document History
- Appendix A: How to Configure and Use the Update Server
- Appendix B: Local R-Key Handling
- Appendix C: Database Maintenance
- Appendix D: Load Balancing
- Appendix E: Update Script for Configuration of Kerberos Clients
- Appendix F: Install Certificate in the Web Browser
- Appendix G: Used IP Ports
- Appendix H: Configure DHCP Options
TD 92579EN
10 April 2015 / Ver. N
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X)
86
3In the Add Radio window enter a name for the device. You can also add a Standby
Master IP Address and a Sync Region.
4 Click "OK".
5 The Radio restarts and it establishes a connection to the PARI Master only.
Delete Radios
In the Static Registrations section, initialized Radios no longer registered to the PARI
Master are shown.
1 Select Device Overview > Radios
2In the Static Registrations section, click "Delete" to delete the Radio.
The Radio’s RFPI is now released and can be reused. All other RFPIs in use are not
affected.
Move RFPIs
In the Static Registrations section, initialized Radios no longer registered to the PARI
Master are shown. If it is vital that the new device keeps the RFPI for the broken device
e.g. alarm localization purposes, move the RFPI for the broken device to the new device
registered to the PARI Master.
1 Connect the replacing device.
2 Add the Radio to the PARI Master, see Add Radios on page 85.
3 Select Device Overview > Radios
4In the Static Registrations section, click "Move" for the Radio that is broken.
5 In the Move RFPI window, select in the Destination section the new Radio that you
want to move the broken Radio’s RFPI to.
6 Click "Move".
Existing RFPI on the new Radio is replaced by the broken Radio’s RFPI. The new
Radio’s RFPI is now released and can be reused. All other RFPIs in use are not
affected. The broken Radio will be deleted from the Static Registrations section.
4.10.2 RFPs
This section only applies to the IPBL.
Information about the DECT devices connected to the IPBL. For explanation on the
information, see the table below.
1 Select Device Overview > RFPs.
2 Click the applicable port to open the RFP details pop-up window.
å
Port The port used in the IPBL.
Status Current status of the IPBS connected to the IPBL.
Description A short description to help identify the IPBS.
Trace file A blue text link for retrieval of a DB1 log. About retrieving a
DB1 log, see
RFP Logging.
RFPI Identity number.
SW Version The current software version.
Hardware The hardware version.