Installation and Operation Manual

Table Of Contents
TD 92579EN
10 April 2015 / Ver. N
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X)
85
1 Select Device Overview > Radios.
Name The unique identification name. The name syntax
is ipbs-xx-xx-xx (IPBS1), ipbs2-xx-xx-xx (IPBS2) or
ipbl-xx-xx-xx (IPBL), where xx-xx-xx should be
replaced with the last 6 hexadecimal digits of the
MAC address.
RFPI Radio Fixed Part Identity.
IP Address The IP address, click on the IP address to access
t
he configuration GUI of that IPBS/IPBL.
Sync The current synchroniza
tion status.
Should be "Master OK", "Slave OK" or "Standby
OK" if
synchronized. "Standby" is a Radio
configured as a Sync Master but it is active.
Region The sync region which the Radio belongs to.
Device Name The name entered in the general menu.
LDAP The LDAP status, can be "" (blank), "-", "up",
"s
erver" or "down".
Should be "-", "up" or "server".
Version The current software version.
Connected Time The elapsed time since connected to the Master.
Add Radios
In the Un
initalized Registrations section, uninitialized Radios not registered to a PARI
Master are shown.
1 Select Device Overview > Radios
2 Click "Add" to add the Radio to the Master.