Installation and Operation Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 IP Security
- 3 Configuration
- 3.1 Requirements
- 3.2 Access the GUI
- 3.3 GUI Web Access
- 3.4 Configure the Mobility Master
- 3.5 Configure the Standby Mobility Master
- 3.6 Configure the Pari Master
- 3.7 Configure the Standby Pari Master
- 3.8 Configure the Master
- 3.9 Configure the Standby Master
- 3.10 Plug and Play Configuration
- 3.11 Configure the Radio
- 3.12 Configure Deployment
- 3.13 Add Users
- 4 Operation
- 4.1.1 Name the IPBS and IPBL
- 4.1.2 Change User Name and Password
- 4.1.3 Centralized Management of Administrator and Auditor Accounts Using Kerberos
- 4.1.4 Configure the NTP Settings
- 4.1.5 Certificates
- 4.1.6 License
- 4.2.1 Set DHCP Mode
- 4.2.2 Set a Static IP Address
- 4.2.3 Dynamic IP address via DHCP
- 4.2.4 Link
- 4.2.5 Configure VLAN
- 4.2.6 View LAN Statistics
- 4.2.7 Enable RSTP (only for IPBL)
- 4.2.8 Deactivate LAN Port (only for IPBL)
- 4.3.1 Configure IP Settings
- 4.3.2 Routing
- 4.4.1 Configure LDAP Server
- 4.4.2 Check LDAP Server Status
- 4.4.3 Configure LDAP Replicator
- 4.4.4 Check LDAP Replicator Status
- 4.4.5 Expert tool
- 4.5.1 Change System Name and Password
- 4.5.2 Set Subscription Method
- 4.5.3 Configure Authentication Code
- 4.5.4 Select Tones
- 4.5.5 Set Default Language
- 4.5.6 Set Frequency Band
- 4.5.7 Enable Carriers
- 4.5.8 Local R-Key Handling
- 4.5.9 No Transfer on Hangup
- 4.5.10 No On-Hold Display
- 4.5.11 Display Original Called
- 4.5.12 Early Encryption
- 4.5.13 Configure Coder
- 4.5.14 Secure RTP
- 4.5.15 Configure Supplementary Services
- 4.5.16 Select Mode
- 4.5.17 Set Master Id
- 4.5.18 Enable PARI Function
- 4.5.19 Set Region Code
- 4.5.20 Configure Gatekeeper
- 4.5.21 Registration for Anonymous Devices
- 4.5.22 Conferencing Unit
- 4.5.23 Select Crypto Master Mode
- 4.5.24 Select Mobility Master Mode
- 4.5.25 Connect Mobility Master to other Mobility Master(s)
- 4.5.26 Disconnect Mobility Master from other Mobility Master(s)
- 4.5.27 Connect Mobility Master to a Crypto Master
- 4.5.28 Connect Master to a Mobility Master
- 4.5.29 Enable the Radio
- 4.5.30 Enter IP Address to the PARI Master and the Standby PARI Master
- 4.5.31 Multiple Radio Configuration
- 4.5.32 PARI
- 4.5.33 SARI
- 4.5.34 Configure Air Synchronization
- 4.6.1 Add instance id to the user registration with the IP-PBX
- 4.6.2 IP-PBX supports redirection of registration when registered to alternative proxy
- 4.6.3 Use local contact port as source port for TCP and TLS connections
- 4.6.4 Session Timer (initial value)
- 4.7.1 Configure Messaging
- 4.7.2 Device Management
- 4.7.3 Service Discovery
- 4.7.4 Send Status Log
- 4.7.5 Module Fault List
- 4.8.1 Configure Automatic Firmware Update
- 4.8.2 Configure Logging
- 4.8.3 Configure the HTTP settings
- 4.8.4 Configure the HTTP Client settings
- 4.8.5 SNMP
- 4.8.6 Phonebook
- 4.8.7 Configure IP-DECT to Connect to a Presence System Using ICP
- 4.9.1 Show all Registered Users in the IP-DECT System
- 4.9.2 Search for User Information
- 4.9.3 Add a User
- 4.9.4 Add a User Administrator
- 4.9.5 Export the Users to a csv file
- 4.9.6 Show Anonymous
- 4.10.1 Radios
- 4.10.2 RFPs
- 4.10.3 Sync Ring
- 4.10.4 Sync Ports
- 4.10.5 Air Sync
- 4.10.6 Sync Lost Counter in IPBS
- 4.11.1 Air Sync Overview
- 4.11.2 Disturbances
- 4.11.3 Status
- 4.12.1 Display All Ongoing Calls in the System
- 4.12.2 Display Calls
- 4.12.3 Handover
- 4.13.1 General
- 4.13.2 Interfaces
- 4.13.3 SIP Interfaces
- 4.13.4 Gatekeeper Interfaces
- 4.13.5 Routes – Configuration
- 4.13.6 Show Active Calls
- 4.15.1 Before Upgrading
- 4.15.2 Upgrading Sequence
- 4.15.3 Software Upgrade from 2.X.X
- 4.15.4 Software Upgrade
- 4.15.5 Configuration After Updating the Firmware From Software Version 2.X.X to Later
- 4.15.6 Configuration After Updating the Firmware From Software Version 3.X.X to Later
- 4.22.1 Update Configuration
- 4.22.2 Update Firmware
- 4.22.3 Update the Boot File
- 4.22.4 Update the RFPs
- 4.27.1 Logging
- 4.27.2 Tracing
- 4.27.3 Alarms
- 4.27.4 Events
- 4.27.5 Performance
- 4.27.6 Config Show
- 4.27.7 Ping
- 4.27.8 Traceroute
- 4.27.9 Environment
- 4.27.10 RFP Scan
- 4.27.11 Service Report
- 4.28.1 Idle Reset
- 4.28.2 Immediate Reset
- 4.28.3 TFTP Mode
- 4.28.4 Boot
- 5 Commissioning
- 6 Troubleshooting
- 7 Related Documents
- Document History
- Appendix A: How to Configure and Use the Update Server
- Appendix B: Local R-Key Handling
- Appendix C: Database Maintenance
- Appendix D: Load Balancing
- Appendix E: Update Script for Configuration of Kerberos Clients
- Appendix F: Install Certificate in the Web Browser
- Appendix G: Used IP Ports
- Appendix H: Configure DHCP Options
TD 92579EN
10 April 2015 / Ver. N
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X)
76
2 Do one of the following:
• To stop the Master to search for a Device Manager, select the Disable check box.
• To set the Master to search for a Device Manager in a specific domain on the
network, enter the domain id in the Domain ID text field. The domain id must be
the same as the one entered in the Device Manager.
3 Click "OK".
When the Master is connected to a Device Manager, the IP address for the Device
Manager is shown in the Unite Address text field under UNITE > Device Management.
4.7.4 Send Status Log
It is possible to send alarm and event reports to the Unite system. For example directly to
the ESS fault handler or to the UNA (Unite Node Assistant) which in turn forwards the
alarm event according to distribution lists.
1 Select UNITE > Status Log.
2 Enter the address to the server where the Status Log should be sent in the Unite IP
Address text field.
3 Enter the Resource Identity/Service in the Unite Resource Identity text field. If this
field is left empty then the default will be UNA (Unite Node Assistant).
4.7.5 Module Fault List
It is possible to change the severity level on alarms and events generated in the IP-DECT
system.
1 Select UNITE > Module Fault List. A list of alarms and events generated in the IP-
DECT system is shown with their fault codes (IP-DECT code and Unite code). Alarms
are listed with a Yes and events are listed with a No in the column Persistant.
2 To change the severity level on an alarm/event: Select in the Seriousness drop-down
list one of the following:
• Disabled (The alarm/event will not be sent to the Unite system.)
• Information
• Warning
• Error
• Critical
3 Click "OK".
Except for severity level Disabled, the alarm/event will be sent to the Unite system
with changed severity level.
4.8 Services
4.8.1 Configure Automatic Firmware Update
The IPBS/IPBL can be configured to automatically update its firmware. A script file must be
uploaded to a suitable directory on an internal web server. For information on the script
file syntax, see Appendix A: How to Configure and Use the Update Server on page 138.
1 Select Services > Update
2 Enter the URL of the script file in the URL text field.
3 Enter the poll interval, in minutes, in the Interval (min) text field