4 If you have selected the "Mirror" mode enter the IP address to the other Mirror
Master in the Mirror Master IP address text field.
For the Master that initially shall be the active Mirror: Click on the text link "Activate
mirror". Any user and handset data in the inactive Mirror will be replaced with the
user and handset data stored in the active Mirror.
To switch the active role between the Mirror Masters, click on the text link "Switch
active mirror". Note: This should be done within a maintenance window as all
active calls will be lost.
5 Click "OK".
6 Reset in order to make the changes take effect, see 4.28 Reset on page 119.
4.5.17 Set Master Id
1 Select DECT > Master.
2 Enter a Master id in the Master Id field. The id must be unique for each Master in a
multiple Master system. The Standby Master must have the same id as the Master.
3 Reset in order to make the changes take effect, see 4.28 Reset on page 119.
4.5.18 Enable PARI Function
The PARI Master is responsible for assigning PARIs, being part of the same external
handover domain, to the Radios associated. A Radio will always be given the same PARI,
based on the PARI-mac-address-association.
1 Select DECT > Master.
2 If this is the Pari Master or standby Pari Master, select the Enable Pari function check
box.
Note: Only one Master per handover and sync domain can have the Pari function
enabled.
3 Reset in order to make the changes take effect, see 4.28 Reset on page 119.
4.5.19 Set Region Code
When placing calls from IP-DECT in a multiple site installation, the IP-PBX has no way of
knowing in which site the user is located because the call is always sent from that user's
Master. Knowing the location becomes especially important for emergency calls.
For more information on region codes, see about Call Localization in the System
Description documentation for IP-DECT.
1 Select DECT > Master.
2 Enter a region code in the Region Code field. The region code can consist of
numbers 0-9, * and #.
4.5.20 Configure Gatekeeper
The Master need to know the address to the system gatekeeper.
1 Select DECT > Master.
2 Select "H.323", "SIP", "TSIP" or "SIPS" protocol in the Protocol drop-down list.
If H323 protocol is selected, continue with step 3 and 4. Otherwise, jump to step 5.
3 Enter the address to the gatekeeper in the Gatekeeper IP address text field.