Installation and Operation Manual

Table Of Contents
TD 92579EN
10 April 2015 / Ver. N
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X)
26
Limitations
Maximum 1000 rows in the csv file.
The maximum csv file size is 128 Kb. If the file is to large, divide the file into several
files.
Only the new user data is imported. The old user data is not deleted.
Existing user data cannot be updated.
If the separator is wrong an error message will be displayed.
The Authentication Code (AC) can not be entered in the csv file for safety reasons. The
system generates a AC for every user in the list. If the user needs the AC the
administrator will have to use Show, see
4.9.1 Show all Registered Users in the IP-DECT
System on page 83.
The software in the DECT Handset must have support for Easy Registration.
Assign Handset to Users
1 Select DECT > System.
2In the Subscriptions drop-down list, select "With User AC" or "With System AC" to
enable easy registration. Click "OK".
3 If "With User AC" have been selected as subscription method:
In the column "IPEI / IPDI", click on the blue text link for the user to allow
subscription within 2 minutes.
4 Perform an "over air subscription" by inserting the battery in the handset. The
handset automatically connects to the IP-DECT system and assigns to the correct
user.