Installation and Operation Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 IP Security
- 3 Configuration
- 3.1 Requirements
- 3.2 Access the GUI
- 3.3 GUI Web Access
- 3.4 Configure the Mobility Master
- 3.5 Configure the Standby Mobility Master
- 3.6 Configure the Pari Master
- 3.7 Configure the Standby Pari Master
- 3.8 Configure the Master
- 3.9 Configure the Standby Master
- 3.10 Plug and Play Configuration
- 3.11 Configure the Radio
- 3.12 Configure Deployment
- 3.13 Add Users
- 4 Operation
- 4.1.1 Name the IPBS and IPBL
- 4.1.2 Change User Name and Password
- 4.1.3 Centralized Management of Administrator and Auditor Accounts Using Kerberos
- 4.1.4 Configure the NTP Settings
- 4.1.5 Certificates
- 4.1.6 License
- 4.2.1 Set DHCP Mode
- 4.2.2 Set a Static IP Address
- 4.2.3 Dynamic IP address via DHCP
- 4.2.4 Link
- 4.2.5 Configure VLAN
- 4.2.6 View LAN Statistics
- 4.2.7 Enable RSTP (only for IPBL)
- 4.2.8 Deactivate LAN Port (only for IPBL)
- 4.3.1 Configure IP Settings
- 4.3.2 Routing
- 4.4.1 Configure LDAP Server
- 4.4.2 Check LDAP Server Status
- 4.4.3 Configure LDAP Replicator
- 4.4.4 Check LDAP Replicator Status
- 4.4.5 Expert tool
- 4.5.1 Change System Name and Password
- 4.5.2 Set Subscription Method
- 4.5.3 Configure Authentication Code
- 4.5.4 Select Tones
- 4.5.5 Set Default Language
- 4.5.6 Set Frequency Band
- 4.5.7 Enable Carriers
- 4.5.8 Local R-Key Handling
- 4.5.9 No Transfer on Hangup
- 4.5.10 No On-Hold Display
- 4.5.11 Display Original Called
- 4.5.12 Early Encryption
- 4.5.13 Configure Coder
- 4.5.14 Secure RTP
- 4.5.15 Configure Supplementary Services
- 4.5.16 Select Mode
- 4.5.17 Set Master Id
- 4.5.18 Enable PARI Function
- 4.5.19 Set Region Code
- 4.5.20 Configure Gatekeeper
- 4.5.21 Registration for Anonymous Devices
- 4.5.22 Conferencing Unit
- 4.5.23 Select Crypto Master Mode
- 4.5.24 Select Mobility Master Mode
- 4.5.25 Connect Mobility Master to other Mobility Master(s)
- 4.5.26 Disconnect Mobility Master from other Mobility Master(s)
- 4.5.27 Connect Mobility Master to a Crypto Master
- 4.5.28 Connect Master to a Mobility Master
- 4.5.29 Enable the Radio
- 4.5.30 Enter IP Address to the PARI Master and the Standby PARI Master
- 4.5.31 Multiple Radio Configuration
- 4.5.32 PARI
- 4.5.33 SARI
- 4.5.34 Configure Air Synchronization
- 4.6.1 Add instance id to the user registration with the IP-PBX
- 4.6.2 IP-PBX supports redirection of registration when registered to alternative proxy
- 4.6.3 Use local contact port as source port for TCP and TLS connections
- 4.6.4 Session Timer (initial value)
- 4.7.1 Configure Messaging
- 4.7.2 Device Management
- 4.7.3 Service Discovery
- 4.7.4 Send Status Log
- 4.7.5 Module Fault List
- 4.8.1 Configure Automatic Firmware Update
- 4.8.2 Configure Logging
- 4.8.3 Configure the HTTP settings
- 4.8.4 Configure the HTTP Client settings
- 4.8.5 SNMP
- 4.8.6 Phonebook
- 4.8.7 Configure IP-DECT to Connect to a Presence System Using ICP
- 4.9.1 Show all Registered Users in the IP-DECT System
- 4.9.2 Search for User Information
- 4.9.3 Add a User
- 4.9.4 Add a User Administrator
- 4.9.5 Export the Users to a csv file
- 4.9.6 Show Anonymous
- 4.10.1 Radios
- 4.10.2 RFPs
- 4.10.3 Sync Ring
- 4.10.4 Sync Ports
- 4.10.5 Air Sync
- 4.10.6 Sync Lost Counter in IPBS
- 4.11.1 Air Sync Overview
- 4.11.2 Disturbances
- 4.11.3 Status
- 4.12.1 Display All Ongoing Calls in the System
- 4.12.2 Display Calls
- 4.12.3 Handover
- 4.13.1 General
- 4.13.2 Interfaces
- 4.13.3 SIP Interfaces
- 4.13.4 Gatekeeper Interfaces
- 4.13.5 Routes – Configuration
- 4.13.6 Show Active Calls
- 4.15.1 Before Upgrading
- 4.15.2 Upgrading Sequence
- 4.15.3 Software Upgrade from 2.X.X
- 4.15.4 Software Upgrade
- 4.15.5 Configuration After Updating the Firmware From Software Version 2.X.X to Later
- 4.15.6 Configuration After Updating the Firmware From Software Version 3.X.X to Later
- 4.22.1 Update Configuration
- 4.22.2 Update Firmware
- 4.22.3 Update the Boot File
- 4.22.4 Update the RFPs
- 4.27.1 Logging
- 4.27.2 Tracing
- 4.27.3 Alarms
- 4.27.4 Events
- 4.27.5 Performance
- 4.27.6 Config Show
- 4.27.7 Ping
- 4.27.8 Traceroute
- 4.27.9 Environment
- 4.27.10 RFP Scan
- 4.27.11 Service Report
- 4.28.1 Idle Reset
- 4.28.2 Immediate Reset
- 4.28.3 TFTP Mode
- 4.28.4 Boot
- 5 Commissioning
- 6 Troubleshooting
- 7 Related Documents
- Document History
- Appendix A: How to Configure and Use the Update Server
- Appendix B: Local R-Key Handling
- Appendix C: Database Maintenance
- Appendix D: Load Balancing
- Appendix E: Update Script for Configuration of Kerberos Clients
- Appendix F: Install Certificate in the Web Browser
- Appendix G: Used IP Ports
- Appendix H: Configure DHCP Options
TD 92579EN
10 April 2015 / Ver. N
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X)
19
1 Determine the address and access the GUI, see 3.2 Access the GUI on page 8.
2 Change the default password, see 3.2.2 Change the Default Password on page 10.
3 Note: This step is not needed if the Master is configured as Mirror. In that case,
jump to the next step.
Configure LDAP user name and password, select the Write Access check box, see
4.4.1 Configure LDAP Server on page 48.
4 Set a static IP address and set DHCP to off, see 4.2.2 Set a Static IP Address on page
44.
5 Set the mode to Active or Mirror, see 4.5.16 Select Mode on page 62.
6 Perform a reset to restart the IPBS/IPBL in Active or Mirror mode, see 4.28 Reset on
page 119.
7 Select system name and password, see 4.5.1 Change System Name and
Password on page 55.
8 Set default language, see 4.5.5 Set Default Language on page 56.
9 Select supplementary services, see 4.5.15 Configure Supplementary Services on
page 60.
10 Set Master id, see 4.5.17 Set Master Id on page 63.
11 Enter gatekeeper IP address or ID, see 4.5.20 Configure Gatekeeper on page 63.
12 Connect to a Mobility Master, see 4.5.28 Connect Master to a Mobility Master on
page 69.
13 Enter IMS3/Unite CM IP address, see 4.7.1 Configure Messaging on page 74.
14 Enter the Time Server address, see 4.1.4 Configure the NTP Settings on page 37.
15 Reset in order to make the configuration changes take effect, see 4.28 Reset on
page 119.
3.9 Configure the Standby Master
It is recommended to have a Standby Master in the IP-DECT system. This section describes
how to configure a Standby Master. Each configuration step is briefly described in the step
list below, for more detailed information see the corresponding subsection in
4 Operation on page 27.
1 Determine the address and access the GUI, see 3.2 Access the GUI on page 8.
2 Change the default password, see 3.2.2 Change the Default Password on page 10.
3 Note: This step is not needed if the Standby Master is configured as Mirror. In that
case, jump to the next step.
Configure LDAP replicator, enter the IP address, user name and password to the
LDAP server. Alternative LDAP server must not be entered. Select the Enable check
box, see
4.4.3 Configure LDAP Replicator on page 48.
4 Set a static IP address and set DHCP to off, see 4.2.2 Set a Static IP Address on page
44.
5 Set the mode to Standby or Mirror, see 4.5.16 Select Mode on page 62.
6 Perform a reset to restart the IPBS/IPBL in Standby or Mirror mode, see
4.28 Reset on page 119.
7 Enter system name and password, this should be the same system name and
password as in the Master. See
4.5.1 Change System Name and Password on page
55.