Installation and Operation Manual

Table Of Contents
TD 92579EN
10 April 2015 / Ver. N
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X)
117
4.27.4 Events
Attribute Description
Time The date and time when the alarm, error is issued or
clear
ed.
Typ e The status of the fault. It has four possible states:
Alarm - Alarms displayed in red are
a
ctive alarms
Alarm cleared - The alarm is already
clear
ed
Alarm timeout - The alarm
e
xceeded the timeout period
Error - Refers to faults that are not
a
ctive for a specific time.
Code A unique number that identifies the alarm.
Click the
code to get more detailed information about the
alarm. For a list of possible codes and their
descriptions, see 6.2 Fault Code Descriptions on
page 124.
Severity It has three possible states:
Critical - Immediate action is
r
equired. It is displayed, for
example, if a managed object goes
out of service.
Major - Urgent action is required. It
is
displayed, for example, if the
capability of the managed object is
severely degraded.
Indeterminate - Level of severity
can
not be determined
Remote The IP Address of the object that r
eported the alarm.
Click the IP address to access the object.
Source The software module that reported the alarm.
T
ogether with the code it uniquely identifies an
alarm.
Description A textual description of the alarm.
Under Diagnostics > Events is history of alarms and err
ors displayed including active
alarms. Click "Clear" in the top-right corner to clear the list of alarms and errors.
For a description of the attributes, see the table below.
4.27.5 Performance
It is possible to check different performance parameters. For a description of the
p
arameters, see the table below.
Parameter Description
CPU Shows CPU utilization. To have a 100% utilization
f
or a longer time is not good but occational peaks
are acceptable. Reason for high utilization may be
caused by running SRTP. Another reason may be
that there are a lot of users registered on the Master.