Installation and Operation Manual

Table Of Contents
TD 92579EN
10 April 2015 / Ver. N
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X)
107
3 Click "Save" in the dialogue window and browse to the place where the
configuration should be saved.
4 Click "Save".
4.15 Software Upgrade
The RFP version information is not displayed in the IPBS2 GUI. RFP software is more
integrated now and this information becomes obsolete. In IPBS1 the RFP software has a
separate flash memory, but this is not the case for IPBS2. On the IPBS1 the RFP version is
still displayed.
4.15.1 Before Upgrading
1 For safety, take a backup of the configuration parameters for the Master and
Standby Master.
2 Make a note of the Master and Standby Master IP address.
On the device configured as Master, continue with step 3 to 5 below.
3 When upgrading from software version 2.X.X to later: Select DECT > SMS and
make a note of the IMS3/Unite
CM IP address.
4 When upgrading from software version 2.X.X to later: Select DECT > Master and
make a note of the SIP proxy (registrar) IP address, found in the Gatekeeper IP
Address text field.
5 When upgrading from software version 2.X.X to later: Select DECT > Master and
make a note of the alternative SIP proxy (registrar) IP address, found in the Alt.
Gatekeeper IP Address text field.
4.15.2 Upgrading Sequence
1 Upgrade firmware and boot file of Standby Mobility Master, see 4.15.3 Software
Upgrade from 2.X.X and 4.15.4 Software Upgrade.
2 Upgrade firmware and boot file of Mobility Master, see 4.15.3 Software Upgrade
from 2.X.X and 4.15.4 Software Upgrade.
3 Upgrade firmware and boot file of Radios, see 4.15.3 Software Upgrade from 2.X.X
and 4.15.4 Software Upgrade.
When upgrading from software version 2.X.X to later: Update configuration of
Radios, see
4.15.5 Configuration After Updating the Firmware From Software
Version 2.X.X to Later.
4 Upgrade firmware and boot file of Standby Master, see 4.15.3 Software Upgrade
from 2.X.X and 4.15.4 Software Upgrade.
When upgrading from software version 2.X.X to later: Update configuration of
Standby Master, see
4.15.5 Configuration After Updating the Firmware From
Software Version 2.X.X to Later.
When upgrading from software version 3.X.X to later: Update configuration of
Standby Master, see
4.15.6 Configuration After Updating the Firmware From
Software Version 3.X.X to Later.
5 Upgrade firmware and boot file of Master, see 4.15.3 Software Upgrade from 2.X.X
and 4.15.4 Software Upgrade.