TD 92579EN PRELIMINARY Installation and Operation Manual IP-DECT Base Station and IP-DECT Gateway (software version 5.x.x) 14 July 2011 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 1 Introduction............................................................................................................. 1 1.1 Abbreviations and Glossary ................................................................................ 2 2 Description............................................................................................................... 3 2.1 IPBS1 ...........
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 5.2 Install the Base Station ..................................................................................... 23 5.2.1 Fix the Mounting Bracket to a Wall .......................................................... 23 5.2.2 Fix the Mounting Bracket to a Ceiling ...................................................... 24 5.2.3 Fix the Mounting Bracket to a Pole or Beam ................
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 7.10 Plug and Play Configuration ........................................................................... 48 7.11 Configure the Radio ....................................................................................... 48 7.12 Configure Deployment ................................................................................... 48 7.13 Add Users ................................
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 8.5.3 Configure Authentication Code ............................................................... 84 8.5.4 Select Tones ............................................................................................. 84 8.5.5 Set Default Language ............................................................................... 84 8.5.6 Set Frequency Band ..................................
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 8.9.4 Import Users from a csv file .................................................................... 100 8.9.5 Export the Users to a csv file .................................................................. 100 8.9.6 Show Anonymous ................................................................................. 100 8.10 Device Overview ............................................
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 8.18.1 Logging ............................................................................................... 124 8.18.2 Tracing ................................................................................................. 125 8.18.3 Alarms ................................................................................................. 125 8.18.4 Events ..........................
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 1.1 TD 92579EN PRELIMINARY Abbreviations and Glossary Base Station Common name for IPBS and DECT Base Station (BS3x0) DECT Digital Enhanced Cordless Telecommunications: global standard for cordless telecommunication.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2 Description TD 92579EN PRELIMINARY This section gives a general description of the following devices: • • • • 2.1 IPBS1, see 2.1 IPBS1 IPBS2, see 2.2 IPBS2 on page 6 IPBL, see 2.3 IPBL on page 10 DECT Base Station, see 2.4 DECT Base Station (BS3x0) on page 13. IPBS1 The following versions of the IPBS1 are available: • IPBS1 with internal antenna • IPBS1 with external antennas 2.1.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) Power Distribution TD 92579EN PRELIMINARY The IPBS1 can be powered using the following methods: • Power over Ethernet, IEEE 802.3af • A local AC-adapter NOTE: For more information about power distribution, see 5.3 Power the Base Station on page 29. Software The software in the IPBS1 can be updated by downloading new software without disconnecting the equipment. The new software is stored in flash memory.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2.1.2 TD 92579EN PRELIMINARY IPBS1 with External Antennas The IPBS1 is available with two omni-directional external antennas. Other external antennas can be mounted as well. This section contains the differences between the IPBS1 with internal and external antennas. For all other information see 2.1.1 IPBS1 with Internal Antenna on page 3.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2.2 TD 92579EN PRELIMINARY IPBS2 The following versions of the IPBS2 are available: • IPBS2 with internal antenna • IPBS2 with connectors for external antennas 2.2.1 IPBS2 with Internal Antenna Front view Back view Reset LED Back view while lying down LAN (RJ45) Used for cable ties to provide strain relief for cables Power Supply (RJ45) Figure 2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY NOTE: For more information about power distribution, see 5.3 Power the Base Station on page 29. Software The software in the IPBS2 can be updated by downloading new software without disconnecting the equipment. The new software is stored in flash memory. See 8.17 Update on page 123 for information.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Error 100 ms red, 100 ms off. No Ethernet connection. Fatal error Solid red. Fatal hardware error. Deployment: Good sync 2000 ms blue, 400 ms yellow. The IPBS2 is in deployment mode and has good air sync coverage. Deployment: Bad sync 400 ms blue, 600 ms off, 400 ms blue, The IPBS2 is in deployment 600 ms off, 400 ms yellow. mode and does not have adequate air sync coverage.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) External Antennas TD 92579EN PRELIMINARY Connect external antennas via the MCX connectors on the IPBS2 before following the installation instructions in 5.2 Install the Base Station on page 23. 14 July 2011 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2.3 TD 92579EN PRELIMINARY IPBL The following versions of the IPBL are available: • IPBL IP-DECT Gateway VAC/VDC (for 110/230 VAC or 48 VDC) • IPBL IP-DECT Gateway VDC (for 48 VDC) Overview base station lan 1 1 2 synchronization 2 ring in 3 ring out 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 reference in 4 out 5 6 006 2.3.1 Figure 4. Overview of the IPBL Pos.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2.3.3 TD 92579EN PRELIMINARY LED indication Status LED Description Not lit Not powered, status is not defined. Flashing slow green When pressing the reset button. Flashing fast green Firmware update or clear config after long reset. Steady green Status OK, system is fully operational. Steady red Status Fail, system error condition. Steady amber System is in TFTP server mode.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Figure 5. Lan LED Description Not lit 10 Mbps operation. Steady 100 Mbps operation. 14 July 2011 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2.4 TD 92579EN PRELIMINARY DECT Base Station (BS3x0) The following versions are available: • BS330 with Internal antenna • BS340 with External antennas 2.4.1 DECT Base Station LED2 Front viewBack view LED1 Test (RJ12) Data/Power (RJ45) Data/Power (RJ45) Figure 5.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) Software TD 92579EN PRELIMINARY The software in the BS3x0 can be updated by downloading new software without disconnecting the equipment. The new software is stored in flash memory. See 8.17 Update on page 123 for information. Connectors • Two 8-pin RJ45 modular jacks for data and powering • A 6-pin RJ12 modular jack for factory testing LEDs 2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 3 Safety Instructions TD 92579EN PRELIMINARY For safe and efficient operation, observe the guidelines given in this manual and all necessary safety precautions. Follow the operating instructions and adhere to all warnings and safety precautions located on the product and this manual. • • • • Installation and service is to be performed by service persons only.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY combination with low humidity. Make sure that the environmental conditions remain within the limits specified in the components’ data sheets. IMPORTANT: 3.2 In the interest of quality and reliability system boards and other parts returned for exchange or credit may be refused if the proper protective packaging is omitted! Safety Aspects 3.2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/tv technician for help. This equipment has been tested and found to comply with the limits for a Class A digital device (IP-DECT Gateway), pursuant to Part 15 of the FCC Rules.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 4 IP Security 4.1 TD 92579EN PRELIMINARY IP Security Terminology 4.1.1 SSL/TLS NOTE: Secure Socket Layer (SSL) has been renamed Transport Layer Security (TLS). TLS 1.0 is based on SSL 3.0/3.1. This document hereafter uses the term TLS. TLS is a security mechanism based on cryptography (see 4.1.3 Cryptography) and is used for encrypting communications between users and TLS-based Websites.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Cryptography tasks can be divided into the two general categories Encryption and Authentication. Encryption Encryption is the scrambling of information so that the original message cannot be determined by unauthorized recipients by applying an encryption algoritm to the message plaintext producing ciphertext (appearently random bits).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 4.2 TD 92579EN PRELIMINARY Introduction to IP Security in IP-DECT A secure system requires more planning than an unsecured system. 4.2.1 Secure Web Access (https) For IP-DECT devices • https access should be enabled • http access should preferably be disabled For more information see 8.1.7 Configure the HTTP settings on page 65 . 4.2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY enterprise CA, enabling them to sign (approve) their own certificate requests. This would make the customer a private CA. - B) Certificates signed by a trusted public third party entity/organization. There are only about a dozen issuers who have the authority to sign certificates for servers worldwide. An example is VeriSign.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 4.3 TD 92579EN PRELIMINARY IP-DECT Administrative Functions 4.3.1 Configuration - HTTP The HTTP Tab is used to configure the type of web access that should be allowed for the device, includes a field for configuring https access. For more information see 8.1.7 Configure the HTTP settings on page 65. 4.3.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 5 TD 92579EN PRELIMINARY Installation of the Base Station This section describes how to install the IPBSs and BS3x0. Both base stations can be fixed to a wall, a ceiling, a pole or a beam, by means of the mounting bracket included. When fixing the base station to a wall or ceiling the included plugs and screws must be used.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Figure 6. Ceiling 65 mm (IPBS1) 100 mm (IPBS2) 011 TOP Figure 6. Fixing the mounting bracket to a wall. 5.2.2 Fix the Mounting Bracket to a Ceiling Fixing to a ceiling is done in the same way as the a wall, see 5.2.1 Fix the Mounting Bracket to a Wall.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Tied wrongly 012 Figure 7. Figure 7. Fixing the mounting bracket to a pole or beam. 5.2.4 Use the Cable Ducts for IPBS1 When the base station IPBS1 is mounted to the wall, cable ducts can be used to route the wiring through. 1 Fix the cable duct to the wall in one of the positions shown in figure 8 on page 26. 14 July 2011 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Figure 8. 65 mm 57 mm TOP 125 mm 70 mm 15 mm thick cable ducts 013 75 mm Figure 8. Minimum distances between a cable duct and the mounting bracket 5.2.5 Secure the Cable For safety reasons secure the base station cable to a convenient point at about 30 cm from the base station. If for some reason the base station drops, it is secured by the cable. 5.2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Pin the IPBS Cable Figure 9. 1 2 Rx Pwr Pwr Rx Pwr Pwr Tx Tx RJ45 modular jack 3 4 5 6 7 8 014 Tx = Transmitter data pair Rx = Reciever data pair Pwr = Power pairs Figure 9. Connector pinning of the LAN/PoE connector, power feed over the spare cable pairs. Figure 10.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 5.2.7 1 TD 92579EN PRELIMINARY Connect the Base Station Cables Only for IPBS1: If it is required that the cables enter the base station centrally from above, guide the cables through the recess in the middle of the base station as shown below. 016 Data cable Power cable (if used) 2 Plug the modular jack of the data cable into one of the data/power connectors.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 5.3 TD 92579EN PRELIMINARY Power the Base Station The base station is powered the following ways: • Power over Ethernet (only IPBS). • Power over Express Powering Pairs (EPP) and data pairs (only BS3x0) • By a local power supply. NOTE: Do not power the base station using both power supplies. Parallel powering will not harm the base station but it can disturb the signalling. 5.3.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 6 TD 92579EN PRELIMINARY Installation of the IPBL This section describes how to install the IPBL. 6.1 Install the IPBL IMPORTANT: To keep the same functionality of the system, do not mix different RFPs, Core (KRCNB 201) and Worf (KRCNB 30x and BS3x0), on the same IPBL. The reason this will not work is prolonged preamle is supported by Worf RFPs but not by Core RFPs.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) consumption. TD 92579EN PRELIMINARY For more information of power consumption of the RFPs, see Appendix B: RFP Power Consumption on page 144. 14 July 2011 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 6.2 TD 92579EN PRELIMINARY Pin the IPBL Cable All data cables used for the IPBL is standard CAT5 unshielded cable. It is assumed that installation personnel know how to crimp these connectors to a cable. 6.2.1 Synchronization Cable The maximum cable length between two IPBLs must not exceed 2000 meters. 1 Cut the cable to the correct length. 2 Connect the cable to a RJ45 modular jack.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 6.2.2 RFP Cable TD 92579EN PRELIMINARY The RFP cable connects the IPBL with the RFPs. The maximum cable length between IPBL and a single RFP must not exceed 1500 meters. NOTE: Ensure that during the installation, each RFP is given an extra length (5-10 metres) of cable because it is possible that it will have to be moved for one reason or another. 1 Cut the cable to the correct length.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 6.3 Power the IPBL TD 92579EN PRELIMINARY The IPBL power supply connectors are located at the rear. The power supply feeds both the IPBL and the connected RFPs. There are two alternatives to power the IPBL: • 110/230 VAC, 60/50 Hz • 48 VDC 6.3.1 110/230 VAC The 110/230VAC (100 – 240 VAC) power input is protected against overload by a 4A fuse.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 6.3.2 TD 92579EN PRELIMINARY 48 VDC The 48 VDC (42 – 56 VDC) power input includes a fuse on the 48 VDC input to protect against overload. The IPBL also has a protection circuit to protect both the IPBL and the external power supply from damages caused by the user reversing the input terminals during installation. Figure 16. 1 2 034 3 Figure 17.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 7 Configuration TD 92579EN PRELIMINARY This section describes how to configure the IPBS and IPBL using the web interface. The recommended order to configure the equipment in the IP-DECT system is as follows: 7.1 1 Configure the Mobility Master, see 7.4 Configure the Mobility Master on page 44. 2 Configure the Standby Mobility Master, see 7.5 Configure the Standby Mobility Master on page 44.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 7.2.1 TD 92579EN PRELIMINARY Determine the IP Address The factory setting of the DHCP mode for the LAN1 port is "automatic", at first power up it will act as a DHCP client. If the network has a DHCP server, it will assign an IP address to the IPBS/IPBL. If there is no DHCP server in the network, the IPBS/IPBL can be assigned a predefined IP address.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY NOTE: If the IPBS/IPBL has been used before, it must be restored to factory default settings by performing a long hardware reset, see 8.20 Reset Using the Reset Button on page 129. Then remove the power supply cable and connect it again. 1 Open a command window in windows by selecting Start > Run and enter "cmd" in the Open: text field. 2 Enter the following commands: C:\ nbtstat -R
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 6 Click "OK". 14 July 2011 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 7.3 GUI Web Access 7.3.1 TD 92579EN PRELIMINARY Login Page When accessing IPBS/IPBL through a web browser the initial page is the login page. This page has two hyperlinks: System Administration and User Administration. NOTE: Logging out of the IPBS/IPBL application is done by closing the web browser, to be completely logged out. 7.3.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY User administrators can only administer users. They can view but not create or manage other user administrator accounts. Login as User Administrator To login as a user administrator: 1 Follow 7.2 Access the GUI on page 36 and access the device using a web browser. 2 Click the link labelled User Administration. A login window is opened.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 3 Enter user name and password for a system administrator. 4 Click "OK" to login. Following tasks can be done: •Managing the default system administrator account, see The Default System Administrator Account on page 42. •Managing additional system administrator accounts, see Additional Administrator Accounts on page 42.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 3 TD 92579EN PRELIMINARY On an existing account row in the Users section:: • • • • 4 Enter a new user name Enter a new password Enter the password again Select Administrator (for System Administrator) or Auditor in the drop-down list (See 7.3.2 Access Levels on page 40 for a description of access levels.) Click "OK". The account row is updated.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 5 PRELIMINARY Select/Edit any of the following settings: • • • • 6 TD 92579EN Long Name Name (NOTE: This field is used for login) Password Confirm Password Click "OK". Delete a User Administrator 1 Login as System Administrator (see 7.3.5 System Administrators on page 41). 2 Select "Users". 3 Click "show".
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 7.6 TD 92579EN PRELIMINARY 3 Set a static IP address and set DHCP to off, see 8.2.2 Set a Static IP Address on page 74. 4 Set the mode to Standby Mobility Master, see 8.5.18 Select Mobility Master Mode on page 91. 5 Enter the primary Mobility Master IP address, see 8.5.18 Select Mobility Master Mode on page 91.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 7.7 TD 92579EN PRELIMINARY 22 Assign PARI, see 8.5.24 PARI on page 93. 23 Enter SARI, see 8.5.25 SARI on page 93. 24 Enter IMS3 IP address, see 8.7.1 Configure Messaging on page 96. 25 Enter the Time Server address, see 8.1.5 Configure the NTP Settings on page 62. 26 Reset in order to make the configuration changes take effect, see 8.19 Reset on page 128.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 7.9 TD 92579EN PRELIMINARY 3 Configure LDAP user name and password, select the Write Access check box, see 8.4.1 Configure LDAP Server on page 76. 4 Set a static IP address and set DHCP to off, see 8.2.2 Set a Static IP Address on page 74. 5 Set the mode to Master, see 8.5.13 Select Mode on page 88. 6 Perform a reset to restart the IPBS/IPBL in Master mode, see 8.19 Reset on page 128.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 12 Enter IMS3 IP address, see 8.7.1 Configure Messaging on page 96. 13 Enter the Time Server address, see 8.1.5 Configure the NTP Settings on page 62. 14 Reset in order to make the configuration changes take effect, see 8.19 Reset on page 128. 7.10 Plug and Play Configuration Radios can be configured from the relevant Pari Master.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY NOTE: For coverage test of air sync, two IPBSs must be configured, one as Sync Master and one as Sync Slave. Each configuration step is briefly described in the step list below. For more detailed information see the corresponding subsection in 8 Operation on page 54. 1 Determine the IP address and access the GUI, see 7.2 Access the GUI on page 36.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY NOTE: Display Name is only used during Active Directory (AD) replication, see Attribute Mappings on page 79. 7.13.1 Anonymous Registration Anonymous Registration is done in two steps. First, the user is registered in the IP-DECT System. Second, the handset is assigned to the user from the handset. Add users in the IP-DECT System 1 Under Administration, select "Users". 2 Click "New".
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 5 TD 92579EN PRELIMINARY Repeat step 3 - 4 for all handsets. NOTE: For safety reasons, when the Anonymous Registration is finished change the Subscription Method to "Disable"otherwise anyone could register to the IP-DECT System. See below for more information. 6 Select DECT > System. 7 Disable anonymous registration by selecting "Disable" in the Subscription dropdown list. Click "OK". 7.13.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 7.13.3 Easy Registration Easy Registration is done in two steps. First, the users are registered in the IP-DECT System through an import of a csv file. Second, the handset is assigned automatically to the user from the handset. Add users in the IP-DECT System If many users should be added it is possible to import a csv file with the IPEI / IPDI. Field name Description Max.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY • The Handset d81 must have version 3.0.X or later. • No other handsets in addition to the above works. Assign Handset to Users "With User AC" must be enabled, see 8.5.2 Set Subscription Method on page 83. When the battery is inserted in the handset, the handset automatically connects to the IPDECT system and assigns to the correct user. 14 July 2011 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 8 TD 92579EN PRELIMINARY Operation This section describes the settings in the Configuration and Administration menu, each subsection represents a sub menu to the Configuration and Administration menu. Some changes require a reset in order to take effect. It is possible to do several changes before resetting the IPBS/IPBL. The GUI for the IPBS and IPBL are similar.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 1 Select General > Admin. 2 Write a user name in the User Name text field. 3 Enter a new password in the Password text field. Repeat the password in the second text field. 4 Click "OK". 8.1.3 ,Centralized Management of Administrator/Auditor Accounts Using Kerberos In software version 3.x.x, each IPBS/IPBL had their own set of administrator/auditor accounts.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) PRELIMINARY 6 Select/Enter the following information for the users of the realm. Field Name Description Name Enter a login user name Password Enter a password Retype Password Confirm password Role • Administrator: Write access to all device parameter settings • Auditor: Read access to device parameter settings • Join Realm: Add devices to the realm 7 TD 92579EN Click "OK".
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Figure 21. Configure the Kerberos client. 1 Select General > Admin. 2 Click on the blue text link "Join realm" in the Delegated Authentication section. 3 In the Join Kerberos realm window, enter the following in the text fields: Realm: Enter the realm name of the Kerberos server. Host name: The MAC address of the device. Default value is used.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY It shall now be possible login to the Radio using the Kerberos login credentials, see Log in using Kerberos on page 58. Configure IPBS/IPBL as a client in a new system Precondition: The IPBS/IPBL must have software version 4.1.x or higher. The idea is to use the Device Overview -> Add to configure the Radios and the Kerberos Client.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2 Click "OK". TD 92579EN PRELIMINARY Configure cross-realm authentication Cross-realm authentication is used to authenticate users from another trusted realm. In this way it is possible for IP-DECT users to login to the IPBS/IPBL using their Windows user name and password in the Active Directory (AD).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Authorization Set user access rights from the Windows domain • Use domain group: Specify a Windows group with Administrator or Auditor rights • Administrator: All Windows domain users have administrator access rights • Auditor: All Windows domain users have auditor access rights Admin Group RID Specify the Relative Identifier (RID) of a Windows group with administrator rights.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2 TD 92579EN PRELIMINARY Login on the client using a Windows server account. When prompted for user name, the name of the Windows domain has to be entered in front of the user name, separated by a backslash in the following way: DOMAIN\username.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY and the IPBS/IPBL is no longer a member of the realm it is not possible to access the IPBS/IPBL in any other way. 1 Select General > Admin. 2 In the Delegated Authentication section clear the Disable local authentication check box. 3 Click "OK". To deactivate the Kerberos membership for a client, do the following: 1 Select General > Admin.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Figure 22. Configure NTP settings 1 Select General > NTP. 2 Enter the IP address to the primary NTP server in the Time Server text field. 3 Enter a time interval in the Interval (min) text field. 4 Select time zone in Time zone drop-down list. If the desired time zone is not in the list, select “Other” and edit the String text field following the instructions in the next step.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY HTTP The syslog entries are transferred to a web server where they can be further processed. Each individual syslog entry is transmitted as form data to the web server in HTTP GET format. HTTPS The syslog entries are transferred to a web server where they can be further processed. Each individual syslog entry is transmitted as form data to the web server in HTTPS GET format.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 2 If the HTTP server destination requires HTTPS then select "HTTPS" in the Type dropdown list. 3 Enter the IP Address of the IPBS/IPBL where you want to have an overview of all faults in the External HTTP Server Address text field. 4 Enter the HTTP server port in the External HTTP Server Port text field. The default value is 80. 8.1.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY • • • traffic (recommended). Attempts to contact the device using the http protocol will result in an Unable to connect message. Enter "HTTPS Port" in the HTTPS Port text field. To access IPBS/IPBL securely, use the TCP port 443 (https). Set this value to anything except zero (0) to enable https traffic. The default value is 443.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Figure 24. Configure SNMP Settings 1 Select General > SNMP 2 Enter a name in the Community field if you are not using the standard community name (public). The community text string acts like a password to regulate access to the agent on the Base Station. 3 Enter a device name in the Device Name field. This field is optional and serves only informational purposes.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Trust List A trust list is set up when the device must know which third parties (for example IP-PBX) it shall trust in. The list contains the certificates to be accepted by the device for TLS secured connections (for example HTTPS, SIPS). The following table describes the different functions.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) Rejected Certificates TD 92579EN PRELIMINARY This list contains the certificate chains that were rejected before, while trying to establish a secure TLS connection. This happens for example if the certificate is expired or neither the certificate nor any of the issuing CAs is trusted. If one of that certificates should be trusted for future connections you can select and add it to the trust list, directly.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) • Upload TD 92579EN PRELIMINARY Use the Upload function to upload a certificate file to the device. 1 Click the Browse button 2 Select a certificate file 3 Click the Upload button to upload the file to the device. NOTE: The Upload function requires a previously issued CSR to exist. Default Device Certificate This section corresponds to option 1 in 2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 3 Select “Self-signed certificate” in the Type drop-down list. 4 Select/Enter the following settings: Field name Description • Validity Enter the default validity in years. This is a mandatory field. • Key Select either the desired key strength (1024-bit, 2048bit, 4096-bit) or select to reuse the old key pair (this is not recommended).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 2 Click the "Create New" hyperlink in the Device Certificate section. A New Certificate window will open. 3 Select “Signing Request” in the Type drop-down list. 4 Select/Enter the following settings: 5 Field name Description • Validity This is an read-only information field indicating a default mandatory validity of 1 year.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY NOTE: If the CSR file generated in step 5 is deleted before receiving the reply from the CA (in step 8) it will not be possible to upload the signed certificate file in step 10. The system will automatically delete the CSR file when step 10 has completed. 8.1.11 License Select Configuration > General > License. Licenses are used to activate additional functions in the IP-DECT system.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 8.2.2 TD 92579EN PRELIMINARY Set a Static IP Address It is necessary for the Master and the Standby Master to have static IP addresses. The Radios can have dynamic IP addresses retrieved from the network DHCP server. Ask the network administrator to reserve an IP address for the Master and Standby Master. 1 On the IPBS: Select LAN > DHCP. On the IPBL: Select LAN1 > DHCP.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 8.2.6 TD 92579EN PRELIMINARY View LAN Statistics To view statistics of LAN events: 1 On the IPBS: Select LAN > Statistics. On the IPBL: Select LAN1 > Statistics. To reset the ethernet statistics counters, click "Clear". 8.2.7 Deactivate LAN Port (only for IPBL) To deactivate LAN port: 1 Select LAN2 > IP. 2 Select the Disable check box. 3 Click “OK”.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 8.3.2 Routing TD 92579EN PRELIMINARY View the IP routing by Select IP > Routing. 8.4 LDAP The Lightweight Directory Access Protocol (LDAP) protocol is required for systems in which the server and a replicating client access a joint user database. All IPBSs/IPBLs in the system have access to the database, one of the IPBSs/IPBLs can be configured to be the LDAP server.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) • • • • • • • • • • 8.4.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY in the IP-DECT system, but it is possible to change or add those user attributes locally that are not replicated. NOTE: If AD replication is enabled, existing local users are replaced with corresponding users in the AD, and some local attributes may be deleted. Contact Ascom Technical Support if you would like to enable AD replication with existing local users.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY • Assignment Pattern - A regular expression that assigns AD attributes to local temporary variables. A local temporary variable can have any name starting with a % sign, for example %tel. Regular expressions are written in a formal language that is widely used in Unix environments. For more information, see regular expression manuals on the internet.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) Example TD 92579EN PRELIMINARY Configure AD Server The IP-DECT system supports only simple binding authentication. However, the default registry setting for Microsoft Active Directory 2003 does not allow simple binds, so it may be necessary to change Windows Registry settings to use AD replication. 1 In Windows, select "Run..." in the Start menu.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 8.4.4 TD 92579EN PRELIMINARY Check LDAP Replicator Status 1 Select LDAP > Replicator-Status. The following information is displayed: • • • • • • • • • • • • • 8.4.5 Server - The IP address and port of the LDAP server. Active Directory Replication - Current state of replication. Four states are possible: Stopped, Starting, Up, Down Remote - State of replication in the source directory.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Figure 25. The DECT System configuration page 8.5.1 Change System Name and Password NOTE: This is only applicable for a Master, never on a Slave. The system name and password must be the same for all IPBS/IPBLs throughout the system. Reset in order to make the changes take effect, see 8.19 Reset on page 128.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 1 TD 92579EN PRELIMINARY Select DECT > System. Note: To access the System tab, the Master mode has to be activated, see 8.5.13 Select Mode on page 88. 2 Select subscription method in the Subscriptions drop-down list. 3 Click "OK". NOTE: When"With System AC" is enabled anyone could register to the IP-DECT System. 8.5.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 3 Click "OK". 4 Reset in order to make the changes take effect, see 8.19 Reset on page 128. 8.5.7 Enable Carriers The IPBS/IPBL has 5 carriers for the North American frequency band and 10 carriers for the other frequency bands. Under all normal circumstances all carriers should be enabled. To enable or disable carriers: 1 Select DECT > System.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2 TD 92579EN PRELIMINARY Choose the applicable coder in the Coder drop-down list. NOTE: The G726-32 coder is not supported by SIP. 3 Enter the sample time in milliseconds in the Frame text field. 4 Choose Exclusive enabled or disabled by selecting/clearing the Exclusive check box. 5 Choose Silence Compression enabled or disabled by selecting/clearing the SC check box. 6 Click "OK". 8.5.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Feature Description Call Completion Busy Subscriber Notifies the caller when a busy number becomes available and reinitiates the call. Only works on H.323 Logout User Logs out the user and the handset becomes anonymously subscribed.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Figure 26. Supplementary services 8.5.13 Select Mode 1 Select DECT > Master. 2 Select in the Mode drop-down list: • • • • "Off", if this IPBS/IPBL is a Slave "Active", if this IPBS/IPBL is the Master. "Standby", if this IPBS/IPBL is the Standby Master. "Deployment" is used for coverage test only. The speech from the handset is looped back to the handset.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2 TD 92579EN PRELIMINARY If this is the Pari Master or standby Pari Master, select the Enable Pari function check box. Note: Only one Master per handover and sync domain can have the Pari function enabled. 3 Reset in order to make the changes take effect, see 8.19 Reset on page 128. 8.5.16 Configure Gatekeeper The Master need to know the address to the system gatekeeper. 1 Select DECT > Master.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY be increased. For example, for 500 users it is recommended to enter 300 seconds and for 1000 users it is recommended to enter 600 seconds. Hold Signalling Some IP-PBXs require special way of hold signalling. In the "Hold Signalling" list field, select one of the following: inactive: No media stream is sent or received. sendonly: Media stream is sent only and not received.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY To ensure two-way authentication the IP-PBX also downloads a certificate from the IPBS. The trust list must also be manually updated with this certificate in the IP-PBX similarly to the IPBS. For more information about certificate handling, see 8.1.10 Certificates on page 67. 8.5.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 3 Enter a password in the Password text field. 4 Enter the address to the other Mobility Master in the IP Address text field. 5 Enter the address to the Standby Mobility Master for the other Mobility Master in the Alt. IP Address text field. 6 Click "OK". 7 Repeat the above steps to connect to additional Mobility Masters. 8.5.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 1 TD 92579EN PRELIMINARY Select DECT > Radio Config. NOTE: To access the Radio Config. tab, the PARI function has to be enabled, see 8.5.15 Enable PARI Function on page 88. 2 Configure alarm and event forwarding, see Forward Alarms and Events on page 64. 3 Configure automatic firmware update, see 8.1.4 Configure Automatic Firmware Update on page 62. 4 Configure NTP settings, see 8.1.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 1 TD 92579EN PRELIMINARY Select DECT > SARI. Note: To access the SARI tab, the PARI function has to be enabled, see 8.5.15 Enable PARI Function on page 88. 2 Enter the SARI number in the SARI text field. 3 Click “OK”. 4 You can add optional guest SARI numbers in the empty field. 5 Click “OK”. All RFPs are reinitialized to broadcast also the added guest SARI. 8.5.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 2 Select "Slave" in the Sync Mode drop-down list. 3 To lock the sync slave to a specific RFPI, enter the sync RFPI in the Sync RFPI text field. Enter an alternative sync RFPI in the Alternative Sync RFPI text field (optional). 4 Enter a region ID between 0 and 63 in the Sync Region text field. 5 Click "OK".
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 8.6.2 TD 92579EN PRELIMINARY IP-PBX supports redirection of registration when registered to alternative proxy When the primary proxy is down and an alternative proxy is in use, the IP-PBX will redirect the registration to the primary proxy when available again. IP-DECT will not make any attempts to contact the primary proxy as long as the alternative proxy is available. 1 Select VoIP > SIP.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2 TD 92579EN PRELIMINARY Select the Multicast checkbox. NOTES: a) The Multicast groups are created in the ESS, refer to Installation and Operation Manual, Enhanced System Services, TD 92253GB. b) In a Multiple Master System all users to be reached by a Multicast message must be assigned to the PARI Master. c) In order to support Multicast messaging the IMS3 must be installed with version 2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2 PRELIMINARY Do one of the following: • • 3 8.7.4 TD 92579EN To stop the Master to search for a Device Manager, select the Disable check box. To set the Master to search for a Device Manager in a specific domain on the network, enter the domain id in the Domain ID text field. The domain id must be the same as the one entered in the Device Manager. Click "OK".
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY First name 1,Last name 1,Telephone number 1 First name 2,Last name 2,Telephone number 2 NOTE: When importing a central phonebook file in csv format, existing entries are deleted. 1 Select "Central Phonebook". 2 Select the Enable check box. 3 Select separator for the csv file in the Delimeter drop-down list. 4 Click "OK". The options Import and Export are displayed.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 2 Enter the name or number to search for in the text field. It is possible to enter only the beginning of the name or number. 3 Click "show". 8.9.3 Add a User For information on how to add Users to the IP-DECT system, see 7.13 Add Users on page 49. For information on how to add Administrator to the IP-DECT system, see Managing User Administrators on page 43. 8.9.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 1 TD 92579EN PRELIMINARY Select Device Overview > Radios. Figure 23. Name The unique identification name. The name syntax is ipbs-xx-xx-xx (or ipbl-xx-xx-xx), where xx-xx-xx should be replaced with the last 6 hexadecimal digits of the MAC address. RFPI Radio Fixed Part Identity. IP Address The IP address, click on the IP address to access the configuration GUI of that IPBS/IPBL.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 3 In the Add Radio window enter a name for the device. You can also add a Standby Master IP Address and a Sync Region. 4 Click "OK". 5 The Radio restarts and it establishes a connection to the PARI Master only. Delete Radios In the Static Registrations section, initialized Radios no longer registered to the PARI Master are shown.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Connected Time The elapsed time since the RFP connected to the IPBL. Cable Delay The delay caused by the cable. Tx Error The number of transmitting errors. Rx Error The number of receiving errors. 3 The following actions are available: • • • • Click "OK" to save your settings and close the pop-up window. Click "Cancel" to close the pop-up window.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY RSSI Received Signal Strength Indication FER Frame Error Rate, a value between 0 and 100%. Should be below 80% to be able to keep the synchronization. 8.10.6 Sync Lost Counter in IPBS This section will describe briefly the different situations when the “sync lost counter” is incremented and what impact it has for the users.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY To see a graphic presentation of the air synchronization in a system, select DECT Sync > Air Sync Overview. The internal synchronization for each region is shown separately by an expandable tree view, see Figure 27.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Reference Synchronization To get the Sync Master to resynchronize to the reference sync, do as follows: 1 Select DECT Sync > Air Sync Overview. 2 Click on the region ID text at top above the sync tree. 3 In the Region Details window, click "Start". When resynchronizing, all ongoing calls in the region will be disconnected. IPBS Details 1 Select DECT Sync > Air Sync Overview.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 8.12 Traffic TD 92579EN PRELIMINARY Traffic information is displayed in the Traffic sub menu. For the Master the traffic information for the IP-DECT system is displayed as well as traffic information for the Radio itself (if this Radio is enabled). 8.12.1 Display All Ongoing Calls in the System All ongoing calls in the IP-DECT system can be displayed by selecting Traffic > Master Calls in the Master.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY SIP interfaces can be used to obtain, for example, a trunk line from a SIP Provider. This solution still requires handset VoIP registrations to be managed in IP-DECT - this is not performed by the SIP provider. 8.13.1 General 1 Select Gateway > General. 2 Select/Enter following settings. 3 Field name Description • Gatekeeper ID The Gatekeeper Identifier.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 8.13.3 SIP Interfaces TD 92579EN PRELIMINARY 1 Select Gateway > SIP. 2 Click on one of the SIP interfaces (SIP1 - SIP4) under the Interface heading. A new window opens.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Media Properties • General Coder Preference Select the applicable coder in the drop-down list. • Framesize Enter the sample time in milliseconds. • Silence Compression Select this check box to enable silence compression. • Exclusive Select this check box to accept only preset coders.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY • Identity Header when Interoperability option for outgoing calls. This controls the way CGPN is transmitted to the SIP provider. Sending INVITE Possible values are: - CGPN is user part of URI - The Identity header contains an URI with the calling party number as user part (left from @). - Fixed AOR - The Identity header contains the fixed registration URI (AOR).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 4 • CGPN out If you want to edit the calling number of outgoing calls. • CDPN in If you want to edit the called number of incoming calls. • CDPN out If you want to edit the called number of outgoing calls. On each mapping line, a Call Number Type can be selected from the Call Number Type drop-down list (found on the righthand side of the lines). NOTE: This step is optional.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY • Third-party VoIP Gateway, as a gateway to telephone switches or, for example, into the SS7 network • Further gatekeepers for call control • VoIP PC programs Each Gatekeeper interface defines access to a group of devices, which are all treated similarly. This allows, for example, all VoIP devices at one location to be configured via a single Gatekeeper interface.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY • Mode Select one of the values below in the Mode drop-down list. Possible values are: - Gateway without Registration - connects to the VoIP interface (gateway) to the configured gatekeeper without a registration. - Register as Endpoint - registers as VoIP terminal with the configured gatekeeper. - Register as Gateway - registers as VoIP gateway with the configured gatekeeper.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY • Supress Subaddress 4 Suppresses the transmission of “Subaddresses” on the interface. Click “OK”. Call Number Mappings Call number (CGPN/CDPN) mappings are described in Call Number (CGPN/CDPN) Mappings on page 111. 8.13.5 Routes – Configuration Call routing determines which calls are able to be accepted by the gateway and where they are to be switched. 1 Select Gateway > Routes.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Number out Name out 117 Number in 3 Select the check boxes of the VoIP interfaces in the left area, to mark them as valid sources for this route. Select interfaces which have been configured. 4 In the drop-down list in the right area, select the destination to which the calls are to be connected. Select interfaces which have been configured.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Leave all the remaining fields blank, in the normal case. • Final Route Enable if the routing shall stop here • Final Map Enable if the mapping shall stop here. • No Reroute on wrong No Enable if you don’t want to reroute when call fails due to wrong number. • Verify CGPN Map will match only if there is a matching CGPN map too.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 3 Under “Number in” define the number type and –prefix that you wish to have replaced. The number type is denoted using the abbreviation from the Call Number Formats Table (see Call Number Formats Table on page 112). 4 Define the substitution under “Number out”. 5 Click “OK”. NOTE: All call numbers in IP-DECT are always processed in “unknown” format.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY State Dialling Dialling is in progress. Alerting The dialled distant terminal is being called. Connected The call is connected. Clearing The call has been terminated by one of the two parties. 8.14 Backup The IPBS/IPBL configuration can be downloaded and saved on a disc or a server.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 8.15.2 Upgrading Sequence The best order is to start with the firmware and boot file upgrade of the Standby Master, then the Master, then all Radios, then do the configuration changes. This way the Radios will not be able to connect to the Master or Standby Master with incompatible firmware.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 4 Reset in order to make the changes take effect, see 8.19 Reset. 5 Update the firmware to 3.x.x. See 8.17.2 Update Firmware for more information on how to update the firmware. 6 Reset in order to make the changes take effect, see 8.19 Reset. 7 Update the boot file to 3.x.x.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 3 To update the Web GUI, press CTRL+F5 on the keyboard or close the Web GUI and start it again in order to make the new menu to appear. 4 Reset in order to make the changes take effect, see 8.19 Reset. 8.15.6 Configuration after System Upgrade from Software Version 3.x.x to 4.x.x When upgrading a system from software version 3.x.x to 4.x.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 2 TD 92579EN PRELIMINARY Select the Enable check box to activate LDAP replication. 8.17 Update This section describes how to do the following configurations and settings. • • • • Update Configuration Update Firmware Update the Boot File Update the RFPs 8.17.1 Update Configuration A previously saved configuration can be loaded and activated on the IPBS/IPBL. See 8.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 2 Click "Browse..." and browse to the RFP update file. 3 Click "Upload". Figure 29. Upgrade the RFP 4 Select "Immediate" or "Scheduled" update. 5 Select "In sequence" check box to update the selected RFPs one by one. 6 Select "When idle" check box to start the update when the RFP is idle. 7 Mark the applicable RFPs to be updated.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY H.323 Registrations Logs generated upon RAS registration. SIP/UDP Registrations Logs generated upon SIP registration. SIP/TCP Registrations Logs generated upon SIP registration. SIP/TLS Registrations Logs generated upon SIP registration. DECT Master Logs generated by the Master software component in the IPBS/IPBL.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Code A unique number that identifies the alarm. Click the code to get more detailed information about the alarm. For a list of possible codes and their descriptions, see 10.2 Fault Code Descriptions on page 133. Severity It has three possible states: • Critical - Immediate action is required. It is displayed, for example, if a managed object goes out of service.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Severity It has three possible states: • Critical - Immediate action is required. It is displayed, for example, if a managed object goes out of service. • Major - Urgent action is required. It is displayed, for example, if the capability of the managed object is severely degraded.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 2 Enter an IP address in the IP Address text field. 3 Press "Enter" on the keyboard. 8.18.8 Traceroute The traceroute function displays how packets travel from the IPBS/IPBL to a certain IP address. The result is an ordered list of IP addresses with the measured round trip time. 1 Select Diagnostics > Traceroute. 2 Enter an IP address in the IP Address text field.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) • • TD 92579EN PRELIMINARY Idle reset - waits until there are no active calls in the IPBS/IPBL. Immediate reset - clears all calls and resets the IPBS/IPBL. 8.19.1 Idle Reset 1 Select Reset > Idle Reset. 2 Click "OK". 3 The IPBS/IPBL will reset when there are no active calls. 8.19.2 Immediate Reset 1 Select Reset > Reset. 2 Click "OK". 3 The IPBS/IPBL will terminate all active calls and reset.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Long press ~ 10 sec. Factory reset - all configuration parameters will be set to default values. For IPBS2: When 10 sec. has gone, the LED on IPBS2 will start to flash in blue, indicating the start of the factory reset process. Hence the reset button can then be released. When the LED (LED 1 for IPBS1) is steady amber/ yellow, the factory reset process is complete.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 9 Commissioning TD 92579EN PRELIMINARY This section describes the visual inspection and tests that must be executed after completing the installation and initialization of the IP-DECT system. The purpose of the visual inspection and tests is to verify that all installation activities have resulted in a correctly functioning system.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY 1 Put all handset together in order of extension number on a table. 2 Go off-hook with each handset and check that the dial tone is heard. 3 Call with a handset (handset A) all other handsets sequentially and check that the handset with the corresponding number on its display rings when called. 4 Call handset A and check if it rings. 14 July 2011 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 10 Troubleshooting TD 92579EN PRELIMINARY 10.1 Load Firmware Using the Gwload Tool If the firmware is corrupt, for example if firmware download is interrupted the IPBS/IPBL could become unreachable by the web GUI. It will not be possible to load new firmware or to start correctly.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Document History For details in the latest version, see change bars in the document. Version Date Description Ver. A 5 February 2009-02-02 First released version. Ver. B 15 April 2009 2009-04-15 Updated 8.7 UNITE on page 96 and added information about device management and service discovery. Ver. C 5 May 2010 2010-03-05 Updated 8.5.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Appendix A: How to Use the Update Server A.1 Summary Automatic update is based on configuration and firmware information stored on a standard web server and retrieved by the devices on a regular basis. There are 2 modules in the device which work in tandem.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) The full syntax is: TD 92579EN PRELIMINARY config change UP1 /url [/poll ] [/poll-fast ] [/disc] If the URL ends with a '/' then a default filename is used based upon the product in question. If for example the URL is "http://1.2.3.4/configs/", it is expanded to "http:// 1.2.3.4/configs/update-IPBS.htm" (.../update-IPBL).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY mod cmd UP1 times [/allow ] [/initial ] The times command will check the current time against . If it does not match this restriction, any further processing of the command file is cancelled. is a comma separated list of hours. Only those hours listed are considered valid times for execution of the command file.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Boot filename IPBS1 boot_ipbs.bin IPBS2 boot_ipbs2.bin IPBL boot_ipbl.bin mod cmd UP0 boot http://192.168.0.10/firm ireset 205 The command above determines if boot code 205 is already installed. If not, new boot code will be downloaded from http://192.168.0.10/firm/boot_ipbs.bin (.../boot_ipbl.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) Example IPBL TD 92579EN PRELIMINARY This example shows an "update file" for the IPBL. mod cmd UP0 prot http://172.20.8.125/ascom/firmware/ ireset 1.0.0 mod cmd UP0 boot http://172.20.8.125/ascom/boot/ ireset 412 mod cmd UP1 check ser 20070316-1 mod cmd RFP_UPDATE0 firmware http://172.20.8.125/ascom/rfp/ Worf123.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Appendix B: RFP Power Consumption The tables below show power consumption for a base station connected to the IPBL. The power consumption of the IPBL is approximately 15 W. Note: The maximum cable length for base stations connected to the IPBL must not exceed 1500 meters. B.1 KRCNB 201/DCT1800 Figure 3. Cable length (metres) 0.4 mm wire size (∅) 0.5 mm wire size (∅) 0.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) B.2 TD 92579EN PRELIMINARY BS3x0 Figure 4. Cable length (metres) 0.4 mm wire size (∅) 0.5 mm wire size (∅) 0.6 mm wire size (∅) 0 EPP 1 EPP 0 EPP 1 EPP 0 EPP 1 EPP 0 5.0 5.0 5.0 5.0 5.0 5.0 100 5.2 5.1 5.1 5.1 5.1 5.1 200 5.3 5.2 5.2 5.1 5.1 5.1 300 5.6 5.3 5.3 5.2 5.2 5.1 400 5.8 5.5 5.5 5.3 5.3 5.2 500 6.1 5.6 5.6 5.4 5.4 5.2 600 6.5 5.8 5.8 5.5 5.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Appendix C: Local R-Key Handling Local R-key handling assume that the check box for local R-key handling is selected, see 8.5.8 Local R-Key Handling on page 85. The following R-key functions are available during a call. Key Description R Put the ongoing call on hold and get a new line. (Dial the number to the second call.) R0 Send busy signal to the incoming call.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Appendix D: Database Maintenance This section describes how IP-DECT user configuration can be moved from one system to another. By moving users, one IP-DECT system can be split into many systems or several IPDECT systems can be merged to one single system.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Appendix E: Load Balancing Load balancing can be used in an IP-DECT system when the number of handsets exceeds what an IP-PBX is able to register. When load balancing the traffic is distributed over several IP-PBXs which can be done in two ways using: • fixed connections for users on each Master towards multiple IP-PBXs.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY dynamically connected towards the IP-PBX network. In addition to the load balancing of the traffic, redundancy is also achivied. IP-PBX IP-PBX IP-PBX Master 0 Pari Master IP-PBX Master 1 Master 2 DNS Server Figure 2. Load balancing using dynamic connection towards IP-PBX network. E.2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY IP-PBX IP-PBX Master 0 Pari Master IP-PBX IP-PBX Master 1 Master 2 WAN DNS Server Master 3 Pari Master Central site Local site proxy server Remote site Figure 3. Redundancy in the remote site using a local site proxy server. E.2.3 About SRV Records Record format An SRV record has the form:. _Service._Proto.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY An example of an SRV record might look like this: _sip._udp.ascom-rd.com. 86400 IN SRV 0 5 5060 sipserver.ascom-rd.com. This points to a server named sipserver.ascom-rd.com listening on TCP port 5060 for SIP protocol connections. The priority given here is 0, and the weight is 5. SRV records must contain the fully qualified domain name (FQDN) of the host.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) E.2.5 TD 92579EN PRELIMINARY Load Balancing Using Dynamic Connection: DNS Server Settings The example below shows the settings in Microsoft Windows Server where the DNS server is installed. 1 From a Microsoft Windows Server with the DNS server installed, open the DNS management tool. 2 Right click the domain (or subdomain) you are assigning this service to and select "Other New Records...". Figure 4.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 4 TD 92579EN PRELIMINARY In the "New Resource Record" window, see Figure 5, do as follows: Enter "_sip" in the Service field. Enter _udp in the Protocol field. Assign a priority and weight. For information on how to set priority and weight, see E.2.3 About SRV Records on page 151. Enter "5060" as the port number. Enter the host name of your SIP server (IP-PBX).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) 7 TD 92579EN PRELIMINARY In the "New Host" window, see Figure 6, do as follows: Enter in the Name field the host name of your SIP server (IP-PBX). Verify that the fully qualified domain name (FQDN) is the correct one. Enter the IP address of your SIP server. Click "Add Host". Figure 6. New host settings 8 Repeat step 1 to 7 for all exisiting IP-PBXs. 14 July 2011 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 5.x.x) TD 92579EN PRELIMINARY Appendix F: Update Script for Configuration of Kerberos Clients The update script is as follows: mod cmd UP1 check resetn serial002 config add NTP0 /addr 192.168.42.136 vars create CMD0/KCMD p