Installation guide

TD 92679GB
12 April 2011 Ver. D
Installation Guide
Elise3
24
Central Unit in the System 900 can distribute the data to a module. Note that this requires
configuration of the Central Unit.
No module addressing
127.0.0.1/S900
The data is sent to the System 900 interface in the Elise3 module, which sends the data on
the A-bus without the module address defined. The Central Unit in the system has to be
configured to distribute the data to a module. It is also possible to address the System 900
interface on another module by entering its IP address instead of 127.0.0.1 (localhost).
Module addressing
127.0.0.1/S900?03
The data is sent to the System 900 interface (127.0.0.1/S900) in the Elise3 module and is
then sent to the module with address 03 in the system. It is also possible to address the
System 900 interface on another module by entering its IP address instead of 127.0.0.1
(localhost).