Installation guide

TD 92679GB
12 April 2011 Ver. D
Installation Guide
Elise3
23
An Elise3 can also set the time in connected systems, for example System 900. In this case,
the Elise3 will send its time to the connected system once every 24-hour period and when
the time is updated.
To set the time in System 900 from the Elise3 do as follows:
1 On the time settings page, enter when the Elise3 should send its time to System
900 in the Time push time field.
2 Click “Setup System 900 time”.
3 Select “Yes” in the Set time in System 900.
Setting time in other carrier systems is done similarly. If several carrier systems are
available, the time will be sent at the same time to all systems.
4.6.5 Time Synchronization
It can take a few seconds to synchronize the date and time during start up or if the IP
address to the time server has been changed.
When the time is changed in the time server, it can take up to 30 minutes to synchronize
the time, depending on how the modules are set up and how they are connected
together.
4.6.6 Message Distribution
In the administration pages, there are distribution lists that are used to distribute incoming
information. The internal distribution is automatically set, but external distribution of
incoming data has to be configured separately.
Distribution of “Status Logs” and “Activity Logs” are configured separately. Advanced
settings for activity logs are described in the
Function Description, Activity Logging in
Unite, TD 92341GB.
The addressing is described in the examples below:
Addressing another Unite compliant module on the LAN
The addressing includes the IP address that the data should be distributed to and also
which service on that address that should take care of it. How a product is addressed is
described in the documentation for each product.
Addressing of another Unite compliant module
xxx.xxx.xxx.xxx/Service
First the IP address of the module is defined. After the “/”, the application service that
should take care of the data is specified.
Below is an example that describes how to distribute data from an Elise3 software
application to an Alarm Management Server.
Addressing of an Alarm Management Server
xxx.xxx.xxx.xxx/EventHandler
First the Alarm Management Server IP address is defined. After the “/”, the application
service EventHandler is specified.
Addressing a module on the System 900 A-bus
When a specific module on the A-bus is addressed, the data will be transferred directly to
that module. It is however not necessary to address a specific module on the A-bus as the