Data Sheet
Table Of Contents
PRELIMINARY
DATA SHEET, Ascom d83 Protector DECT Handset
Environmental
Operating temperature: −10°C to +55°C (+14°F to +131°F)
Storage temperature
1
: −20°C to +60°C (−4°F to +140°F)
Charging temperature: +5°C to +40°C (+41°F to +104°F)
Immunity to electromagnetic fields: 10 V/m
(EN 61000-4-3)
Immunity to ESD: 8 kV contact discharge and 16 kV air discharge
(EN 61000-4-2)
Enclosure protection: IP67, IEC EN 60529
Free fall test: IEC 60068-2-31, procedure 1, dropped 12 times, specification extended
to 2 m
IEC 60068-2-31, procedure 2, dropped 1 000 times from 0.5 m
Chemical resistance test: 3% Hydrochloric Acid
M-alcohol (85% methylated ethanol)
60% Chlorhexidin 0.5 mg/ml
Accelerated Life Testing
Climate stress: Handset exposed to quick temperature and humidity changes
Temperature: -40°C to +75°C
Humidity: 0% to 90%
Drop test: Handset dropped 30 times from 1.2 m (6 times each loop for 5 loops)
Vibration test: Handset exposed to 30 Hz vibrations for a duration of 2.5 h
Chemical stress: Handset exposed to Oleic Acid
Keypad actuation test: Keys pressed 15 000 times with a force of 13 N
Squeeze test: Handset squeezed 1 000 times with a force of 130 N
Specifications are subject to change without notice
TD 93420EN / / Ver.