Product manual
Upgrade from DCT1800-A to DCT1800-GAP R2A – July 1999
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
21
4.3 Use of the Line Termination Unit, LTU - ROFNB 157 25/n
The table below gives an overview of which LTU version should be used in a particular situation. As
can be observed LTU ROFNB 157 25/2 can be used is most cases. LTU ROFNB 157 25/1 should
only be considered as an alternative if the /2 version can not be used due to temperature limitations,
see section 4, ’Configuration directions’, paragraph ’Modular cabinet temperature limitations’, or if the
/2 version does not satisfy type approval requirements in countries outside the EC and EFTA.
ROFNB 157 25/1 and ROFNB 157 25/2 can not be used together in one system.
2
Note 1:
LTU ROFNB 157 25/2 is not nationally type approved for use of the ’pulse dialling’ and ’register recall’
functions.
4.4 Upgrading a DCT1800-A to DCT1800-GAP R2A system
When updating a DCT1800-A system to a DCT1800-GAP R2A system all except the following system
components can be reused:
• Central cabinet BFLNB 101 05/n and related products such as cables and power supply.
• Cordless phone DPANB 201 0x/3
• CPU board 2/ROFNB 157 06
• CPU firmware RYT/ROFNB 157 06/2
• SPU board ROFNB 157 08/n
• DTU-E1 CAS firmware set NTM/RYSNB 101 17/1
• DTU CAS firmware RYT/ROFNB 157 03/2
• Cordless system manager software LZYNB 201 01
• Cordless system statistics software LZYNB 201 02
Product name Product number Remarks
Portable data management tool (PDMT) LZYNB 101 04/n For system administrator and distributor
Programmer set NTM/DPYNB 101 06/n For cordless phones DT310, DT360, DT368
DT310 GAP software upgrade diskette LZY/DPANB 208 01/n Diskette with upgrade software for the DT310 GAP
DT360 GAP software upgrade diskette LZY/DPANB 209 01/n Diskette with upgrade software for the DT360 GAP
DT368 GAP software upgrade diskette LZY/DPANB 209 10/n Diskette with upgrade software for the DT368 GAP
Table 9 Replaced products
LTU board EC and EFTA countries Non EC or EFTA countries
PABX PSTN PABX PSTN
TBR21
required
No TBR21
required
TBR21 always
required
(2)
ROFNB 157 25/1 Alternative Alternative Alternative
ROFNB 157 25/2 Must be used Recommended Must be used Recommended Recommended
Table 10 Use of LTU ROFNB 157 25/n