Product manual
Upgrade from DCT1800-GAP R1A to R1B – January 1999
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
11
Fig. 3 Service form
Service form to file
Menu path: System manager - Control - Service form - To file
• This command has been added. It writes the service form information to a file after specifying
the destination directory and file name (see figure
3). For information about the contents see
paragraph .
001
Cordless System Manager Service Form
DCT1800-GAP system
Software version of CSM : xxxx
Time of form creation : 98-09-07 15:00:07
Fault table:
No error messages logged in this buffer.
Service table:
No error messages logged in this buffer.
Information table:
No error messages logged in this buffer.
System information:
Addr | Type | BC | P1 | P2 | P3 | P4 | P5 | P6 | P7 | P8 |
-------------------------------------------------------------------
1 24 | CPU HSCX=AVE Poll proc.=AVE CPU body=AVE
| HWA=AVE HWB=AVE HWC=AVE
1 32 | LTU AVE AVE AVE AVE AVE AVE AVE AVE AVE
1 44 | CLU AVE AVE PNP PNP PNP PNP PNP PNP PNP
| SPU AVE AVE AVE AVE AVE AVE AVE AVE AVE
Software version table:
Addr | Type | Firmware | Bootcode/ABC number
--------------------------------------------------
1 24 CPU R2A CAHNB 201 27/1
1 32 LTU R2B STD
1 44 CLU R1B
1 44 1 RFP R1B 1/01 R6B
1 44 SPU SPUS-R2A