Product manual
Upgrade from DCT1800-GAP R1A to R1B – January 1999
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
9
This menu has changed. The following detection options are available (see figure 1):
• Tone detection, clear at time-out
If no dial tone is detected the cordless phone goes automatically on-hook after the time-out.
• Tone detection, continue at time-out
If no dial tone is detected the radio exchange (and cordless phone) continues with dialling out
the numbers after the time-out.
• Pause, continue after time-out
The radio exchange (and cordless phone) waits for a fixed period of time before proceeding with
dialling out the numbers.
Note:
The time-out values of the three options must be equal or greater than the value specified for the SPU-
S parameter ‘Dial tone detection time’ (Menu path: Distributor - System - Parameters - Customize -
SPU-S).
Fig. 1 Wait for dial tone
Download one base
Menu path: Distributor - Base station - Download - One base
This command has changed. You can now specify date and time when CSM should start downloading
software from the PC into a specified base station.
Download all bases
Menu path: Distributor - Base station - Download - All bases
This command has changed. You can now specify date and time when CSM should start downloading
software from the PC into all the base stations.
WAIT FOR DIAL TONE
________________________________________________________________________________
Wait for dial tone Options
___________________________________ _______________________________________
Wait for dial tone : 1 1. Tone detection, clear at time-out
2. Tone detection, continue at time-out
3. Pause, continue after time-out
Time-outs in milliseconds:
Tone detection and clear : 10000 (0, 100, 200, 300, ... , 60000 ms)
Tone detection and continue : 3000 (0, 100, 200, 300, ... , 10000 ms)
Pause and continue : 3000 (0, 100, 200, 300, ... , 10000 ms)
________________________________________________________________________________
<Esc> Continue-<F5> Quit-<F10> <←> <→> <↑> <↓> <Enter>