2.2 Error handling
The test & maintenance software in the CPU, abbreviated to T&M, is activated either upon the reception
of operational faults, or when a test has to be executed. A description of tests that T&M can perform
is found in paragraph
2.3. This paragraph deals with fault handling.
Operational faults and faults detected during tests will cause T&M to start up a fault handling procedure
by which T&M tries to verify and clear the error. Figure
2 shows the different steps of the fault handling
procedure. The two conditions for reception of a fault message cause the start of the flow.
All messages received by T&M are stored in either the info or the fault table. Some messages are of
the category ‘information only’. In that case the message is logged in the info table with the status
code L (logged). In case of a failure, a message will be written in the fault table. When the message
deals with a hard fault, an additional fault report will be written in a third table called service table.
This applies in general for faults causing system performance degradation.