Fig. 117 DTU/MCCB cable – REX-CAB9015 (TSRNB 101 37)
25.19 LTU/MDF cable set, long – REX-CAB9004 (NTM/TSRNB 101 44)
The LTU/MDF cable set long (see figure 118) is used for the connection of the LTU to an MDF. It
consists of two shielded cables with a connector at one side. The shield of the cable is connected to
the modular cabinet by a clamp. The only difference between the two cables is the location of this
clamp on the cable. The clamp is placed on respectively 325 mm from the connector for the TSRNB
101 44/1, and 445 mm for the TSRNB 101 44/2. The clamp also functions as a pull-relief.
Revision R2 is provided with a ferrite core for EMC reasons.
The length of the cable is 25 m.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
10
9
10
RECEIVE
RECEIVE SHIELD
SEND
SEND SHIELD
K1 K2
notch >
1
3
4
5
6
7
8
9
10
2
notch >
1
3
4
5
6
7
8
9
10
2
K1
K2
X1 X2
480 mm 10 mm
Ferrite bead core
Cable is looped
three times around
the core
±