Installation instructions, Cables
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
158
25.12 General alarm cable – TSRNB 101 28
The general alarm cable (see figure 110) is used to connect the general alarm output of the CPU to
the MCCB. This cable does not need to be ordered separately. It is factory connected to the MCCB.
Fig. 110 General alarm cable – TSRNB 101 28
25.13 CLU/MDF cable set – REX-CAB9001 (NTM/TSRNB 101 29)
The CLU/MDF cable set (see figures 111 and 112) consists of two shielded cables (TSRNB 101 29/1
and TSRNB 101 29/2). The cables are used to connect a CLU REX-BRD0014 (ROFNB 157 11), CLU-
S REX-BRD0016 (ROFNB 157 16/2) or a SLU REX-BRD0015 (ROFNB 157 16/1) to an MDF. The
shielding of the cables is connected to the cabinet via a clamp which also functions as a pull relief.
The only difference between the two cables is the location on the cable where the clamp is attached
to the shielding. This is respectively 325 mm from the connector for cable TSRNB 101 29/1 and 470
mm for cable TSRNB 101 29/2.
K2
45mm
± 5mm
170 mm
±
10
mm
K1
8
75
6
3
4
1
2
12K1
K2
notch >
1
2
3
4
5
6
7
8
k1
green
yellow
1
2
k2
091