Product manual
Installation instructions, Modular cabinet power cabling
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
108
Fig. 70 Schematic diagram of powering the modular cabinet and 3 CLUs/CLU-Ss/SLUs
by a transformer and 5 CLUs/CLU-Ss/SLUs by a 48 Vdc supply
1. Connect the power cable (TRENB 101 01) in the modular cabinet to the power transformer.
2. Make a cable like TRENB 101 01 by crimping two faston connectors at one end of a 2.5 mm
2
2-
wire cable with a length of about 2.5 m.
3. Connect this cable to the PW-EXT connector on the MCCB. See figure 71 for the polarity.
4. Connect the power supply at the other end of the cable.
5. Connect the positive pole of the power supply to the ground of the modular cabinet by repositioning
the ground bridge, when local regulations require this.
Note:
There are two sets of PW1, PW2 and PW3 terminals; one for backplane powering and one for external
powering.
WARNING
When using the PBX power supply, make sure that the capacity of the
supply is sufficient to power both the PBX and the modular cabinet.
Modular
cabinet
Internal
48 Vdc
Backplane
PW-
EXT
PW-
BP
5
3
CLUs,
CLU-Ss
or SLUs
Transformer
MCCB
055