Product manual
Installation instructions, Modular cabinet power cabling
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
104
Factory fitted power cabling
The modular cabinet is delivered with the following powering cables fitted:
• Power cable TRENB 101 01 connected to the bottom side of the filter (see figure 65)
• Cable TRENB 101 02 between the filter and the power switch (see figure 66)
• Cable TRENB 101 04 between the switch and the two fuse holders
• Cable TRENB 101 05 between the fuse holders and connector X102 on the backplane (see figure
67. The end of the cable with the piggy-back faston is connected to the backplane
• Cable TRENB 101 03 between connectors X112/X113 and connector PW-BP and the MCCB
All cables are connected with the red wires (+) connected at the left-hand side. The red wire of cable
TRENB 101 03 is connected to connector X112 (+).
In the following paragraphs it is assumed that the cables are fitted as described above. So if you
altered the wiring, change it as described above.
Fig. 65 Power connection to the modular cabinet
Power
cable TRENB 101 01
DC: +
DC: −
Black
Red
Botton view
050