Product manual

Installation instructions, Modular cabinet connection board – REX-SPP0014 (ROANB 101 28)
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
98
Fig. 60 Power distribution on the MCCB
Fuses
The MCCB is provided with two fast 15 A fuses (see figures 60 and 63) to protect the external power
supply from short circuit. Only use the following fuses: REX-SPP0002 (NGHNB 101 103), 15 A/250 V.
Ground bridge setting
The ground bridge connects the plus pole of PW-EXT to ground (see figure 60). Default it is in the
unconnected position. Connect the ground bridge to ground if local regulations require it.
Jumper settings
The MCCB is provided with jumpers to connect the cable shield of the PBX cables to ground.
PW-BP
PW1
PW2
PW3
PW5
PW6
PW7
PW4
PW-EXT
Fuse
F1
Fuse F2
Power filter
Power filter
PW1
PW2
PW3
Backplane power
External power
Ground
bridge
MCCB
045
+