Product manual

Installation instructions, Speech Link Unit (SLU) – REX-BRD00015 and REX-BRD00026
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
51
Chapter 11 Speech Link Unit (SLU) – REX-BRD00015 and
REX-BRD00026
11.1 General
The SLU is a combination of an SPU-S and a CLU-S on one board. The CLU-S part is used to control
base stations via twisted pair cables with a length of maximum 2.1 km. For longer cables (up to 3.5
km), the CLU with product code REX-BRD0014 (ROFNB 157 11/2) must be used.
Power distribution to the base stations is protected by two PTCs for each base station (see figure 30).
Maintenance
The SLU contains the following field-exchangeable parts (see figure 29):
SPU-S board controller firmware
CLU-S board controller firmware
11.2 Board description
Jumpers
Not applicable.
Connectors
The CLU-S part has the following connectors at the front:
8 connectors (CLC1 - CLC8) by which the Cell Link Circuits (CLCs) are connected to the base
stations
1 connector (base station power) to connect a power supply voltage from the connection board
for powering the base stations when no AC-adapters are used. The power connector does not
have a polarity. It makes no difference which pin becomes plus or minus.
LEDs
SPU-S part:
LED1 : Normally on. Power on LED SPU-S
LED2 : Normally off. Watch-dog LED SPU-S (not significant)
LED3 : Normally off. Board not polled LED SPU-S
LED4 : Normally off. Board error LED SPU-S
CLU-S part:
LED1 : Normally on. Power on LED CLU-S
LED2 : Normally off. Watch-dog LED CLU-S (not significant)
LED3 : Normally off. Board not polled LED CLU-S
LED4 : Normally off. Base station in NEW state or board error CLU-S