Fig. 26 Power distribution on CLU
9.3 Installation
1. Insert the CLU into the slides of its specified slot position.
2. Gently push the board into the back connector till it locks. Don’t use any force.
Note: Since the base stations must be initialized connected to one CLU board at the time, it is
recommended to start with inserting only one CLU board at the first installation. When the connected
base stations have been initialized, the second CLU board can be inserted and base stations initialized,
etc.
Note:
See also chapter 22 ‘CLU/CLU-S/SLU to base station cabling’.
Power from
connection board
CLC 8
P0
P1
SC0
SC1
Base station 8
CLC 1
SC0
SC1
EPP
Base station 1
CLU
EPP