Product manual
Installation instructions, Power transformer – REX-BAS006n (RES 147 006/n)
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
22
5.2 Description
The power transformer can power one modular cabinet and a number of base stations. The transformer
shall be mounted to the wall. The transformer is connected to the modular cabinet using a cable
(TRENB 101 01) delivered with the cabinet. In case of short-circuit the automatic fuse will activated.
The fuse can be reset by pressing the reset button.
The power transformer is supplied with a fixed power cord. The plug at the power cord is dependent
on the transformer version.
5.3 Installation
1. Drill three holes using the drilling template found on the cover of the cardboard box of the power
transformer.
2. Insert the wall plugs if necessary.
3. Remove the screw in the cover.
4. Position a screw driver at the back of the transformer as indicated in figure 14 and turn the screw
driver gently until the cover snaps open.
5. Make a hole in the cable feed through plate (see figure 13) using a knife, to feed the power cable
(TRENB 101 01) from the modular cabinet through.
6. Feed cable TRENB101 01 through the plate and connect the cable to the screw connector.
7. Mount the power transformer to the wall using the 3 screws delivered with the transformer.
8. Fix the cover and fasten the screw again.
WARNING
Never operate the power transformer without its cover.