Installation instructions, Modular cabinet – REX-BAS900nn (BDVNB 101 01/16)
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
19
Fig. 11 Ground strip
4.10 Connection of wrist strap for ESD
After mounting the modular cabinet(s) the engineer must avoid damaging the system boards by ESD.
Therefore the engineer must use a wrist strap which must be connected to the cabinet at the connector
indicated in figure
5.
Note:
The modular cabinet must be connected to protective ground otherwise there will be no protection.
4.11 Placing the securing bar
After all system boards have been placed into the cabinet(s), mount the securing bar(s) as shown in
figure
12.
WARNING
To prevent the ground connection from contact corrosion, only a
ground cable with a tinned eye should be connected to the ground strip.
Protective
ground
connections
Cable tie blocks