Product manual
Installation instructions, Modular cabinet – REX-BAS900nn (BDVNB 101 01/16)
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
11
Chapter 4 Modular cabinet – REX-BAS900nn
(BDVNB 101 01/16)
4.1 Contents of the box
The cardboard box of the modular cabinet contains the cabinet and the following material:
• 1 mounting bracket
• A bag with;
– Cabinet mounting material:
– 4 wall plugs (8 mm)
– 4 screws (∅5 × 30)
– 10 tie-wraps
– 32 M3 × 6 screws with torx heads for cable clamps
–2 M4 × 6 screws with torx heads and washers for protective ground cable
– 6 cable tie blocks
• Label stickers
4.2 Fuses
The modular cabinet is provided with 4 fuses:
• 2 fuses near the power switch (see figure 5)
• 2 fuses on the MCCB (see chapter 19)
Only use fuses of the following type: REX-SPP0002 (NGHNB 101 103), 15 A/250 V.
4.3 Installation area of the modular cabinets
• The radio exchange may consist of up to 4 modular cabinets. The modular cabinets must be
mounted next to each other (see figure
4).
• The modular cabinets must be mounted to the wall at a position where it is easily accessible for
installation and maintenance. Take into consideration that the number of cabinets may be
extended in future.
• The modular cabinets should be mounted at the normal working height. The lower edge of the
modular cabinets should be about 1.60 m above the floor.
• Above the modular cabinets there should be at least 0.1 m free space for air circulation.
• Modular cabinets must be separated approximately 8 mm from each other.