Product manual

Installation instructions, Modular cabinet – REX-BAS900nn (BDVNB 101 01/16)
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
11
Chapter 4 Modular cabinet – REX-BAS900nn
(BDVNB 101 01/16)
4.1 Contents of the box
The cardboard box of the modular cabinet contains the cabinet and the following material:
1 mounting bracket
A bag with;
Cabinet mounting material:
4 wall plugs (8 mm)
4 screws (5 × 30)
10 tie-wraps
32 M3 × 6 screws with torx heads for cable clamps
–2 M4 × 6 screws with torx heads and washers for protective ground cable
6 cable tie blocks
Label stickers
4.2 Fuses
The modular cabinet is provided with 4 fuses:
2 fuses near the power switch (see figure 5)
2 fuses on the MCCB (see chapter 19)
Only use fuses of the following type: REX-SPP0002 (NGHNB 101 103), 15 A/250 V.
4.3 Installation area of the modular cabinets
The radio exchange may consist of up to 4 modular cabinets. The modular cabinets must be
mounted next to each other (see figure
4).
The modular cabinets must be mounted to the wall at a position where it is easily accessible for
installation and maintenance. Take into consideration that the number of cabinets may be
extended in future.
The modular cabinets should be mounted at the normal working height. The lower edge of the
modular cabinets should be about 1.60 m above the floor.
Above the modular cabinets there should be at least 0.1 m free space for air circulation.
Modular cabinets must be separated approximately 8 mm from each other.