Chapter 2 Safety
2.1 Safety rules
Ensure that the voltage and frequency of the mains power socket matches the voltage and
frequency inscribed on the equipments electrical rating label.
Never install telephone wiring during a thunderstorm.
Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
Never touch un-insulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
Note: Avoid touching or punching down the Base Station signal and power pairs as there is -48Vdc
present on these wires at all times.
Use caution and observe all relevant safety standards when installing or modifying telephone lines.
Always install conform relevant national installation rules.
Only mount the radio exchange to a wall.
Do not mount the modular cabinet to a drywall using insertable plastic drywall plugs. These will
not safely support the cabinet. See Installation section for recommended mounting.
Suitable for mounting on concrete or other non-combustible surface only. [This refers to the floor
covering/material beneath the cabinet(s)].
Disconnect all power sources before servicing equipment.
Make sure that the radio exchange is connected to telecom or protective ground.
Avoid using a telephone (other than a cordless type) during a thunderstorm. There may be a
remote risk of electric shock from lightning.
Do not use the telephone to report a gas leak in the vicinity of the leak.
In areas with potentially explosive atmospheres only cordless phones may be used. Use of other
types of cordless phones in such areas may cause a risk of explosion.
The Modular Cabinet must be mounted in a restricted area.
The power source must be short circuit protected (15 A maximum).
For the Modular Cabinet use Class II power sources, double insulated conforms to (EN60950
(Europe) Uout 42 Vac rms or 58 Vdc) or (UL1950 (US & Canada) Uout 58 Vdc) only.
The power source branch circuit over current protection must be rated 15A. The power source
must be short circuit protected (15A maximum).
Only approved power supplies according to valid editions of EN/IEC/CSA/UL/AU/NZS 60950 are
to be used when the base stations are powered by local power supplies.
Use only approved spare parts and accessories. The operation of non-approved parts cannot be
guaranteed and may even cause damage or danger.
Service is to be performed by qualified personnel only.