Chapter 8 Cables
Mains power cord – REX-CAB9016 (RPM 945 102)
To connect power supply unit (BML 351 013/1) to mains. For European countries except U.K., Ireland
and Cyprus
Interconnection set – REX-CAB9008 (NTMNB 101 105)
To interconnect two adjacent modular cabinets.
Flat cable : Connects the backplanes, two 34-pin connectors
Shielding gaskets (4) : Connects the metal housing of the cabinets
Safety ground cable : Connects the ground of the cabinets
CLU/MDF cable set – REX-CAB9001 (NTM/TSRNB 101 29)
This cable set consists of two similar cables. The only difference is the position of the shielding clamp.
Cable length : 5 m
Wires : 12 twisted pairs
Connector CLU side : 32 pins, DIN41612
Connector MDF side : none
LTU/MDF cable set – REX-CAB9002 (NTM/TSRNB 101 31)
This cable set consists of two similar cables. The only difference is the position of the shielding clamp.
Cable length : 5 m
Wires : 4 twisted pairs
Ferrite core : for revisions R2
Connector LTU side : 16 pins, DIN41612
Connector MDF side : none
CLU/MCCB power cable – REX-CAB9013 (TSRNB 101 33)
Cable length : 50 cm
Wires : 2
Connector CLU side : 2 pins, Ericsson power connector
Connector MCCB side : 2 pins, MOLEX mini-fit, Jr
LTU/MCCB ground cable – REX-CAB9014 (TSRNB 101 35/2)
Cable length : 35 cm
Wires : 4, only 2 wires are used
Connector LTU side : 8 pins, DIN41612
Connector MCCB side : 2 pins, MT connector
DTU/MCCB cable – REX-CAB9015 (TSRNB 101 37)
Cable length : 48 cm
Wires : 2 coaxial pairs
Connector DTU side : 10 pins, DIN41612
Connector MCCB side : 10 pins, DIN41612
LTU/MDF cable set, long – REX-CAB9004 (NTM/TSRNB 101 44)
As for REX-CAB0002 (NTM/TSRNB 101 31) with the following exception:
Cable length : 25 m