Product manual
Product specifications, Power supply units
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
19
Chapter 7 Power supply units
7.1 AC-adapter – BMLNB 101 09/n
This adapter is used to power a BS330 (KRCNB 301 02/n, KRCNB 301 03/n, KRCNB 301 04/n),
BS340 (KRCNB 302 01/1) or a BS370 (KRCNB 302 01/1) type base station.
Versions
BSX-0013 BMLNB 101 09/1 : For European countries except U.K.
BSX-0014 BMLNB 101 09/2 : For U.K. (different mains plug)
BSX-0015 BMLNB 101 09/3 : For US/Canada
BSX-0016 BMLNB 101 09/4 : For Australia
Compliance to regulations and standards
Safety : IEC950 and EN60950
EMC : ETS 300 329
EN61000-3-2
EN61000-3-3
Environmental
Operating temperature : −10 °C to +55 °C
Storage temperature : −40 °C to +70 °C
General specifications
Length x width x height : 96 mm x 63 mm x 48.5 mm
Length of cable from adapter : 10 m
Plug secondary side : 8-pins RJ45
Primary voltage : depending on version
Secondary voltage : 24 Vdc ± 5%
Maximum secondary current : 250 mA (1 A short circuit)
Protection : Against short-circuit and over-voltage
Note:
Only approved power supplies according to valid editions of EN/IEC/CSA/UL/AU/NZS 60950 are to
be used when the base stations are powered by local power supplies.
7.2 Power transformer – REX-BAS006n (RES 147 006/n)
Versions
REX-BAS0060 (RES 147 006/1) : For European countries except U.K.
REX-BAS0061 (RES 147 006/2) : For Australia
REX-BAS0062 (RES 147 006/3) : For U.K. (different mains plug)
Compliance to regulations and standards
International : EN60950, IEC742, AS3108
General specifications
Design : Class II
Width x depth x height : 190 x 180 x 106 mm
Weight : approx. 4.3 kilograms