Product manual
Product specifications, System boards
Technical Product Manual - DCT1800-GAP
TD 92093 (1/LZBNB 103 108 R4D) / 2006-03-09/ Ver.C
© 2006
15
Transport data rate
384 kbit/s
Maximum length base station cable
For KRCNB 301 and 302 base stations of revision R3n and later, maximum length is 1.9 km with
standard CAT5 cable (FTP CAT5e 4x2x0.5).
For older base stations like KRCNB 201 base stations and 301and 302 base stations of revision R1n
or R2n, maximum length is up to 3.5 km.
General specifications
Length x width : 344 x 195 mm
5.12 Cell Link Unit-S, CLU-S – REX-BRD0016 (ROFNB 157 16/2)
Environmental
Temperature
Operating : 0 to 70 °C
Storage : −40 to 70 °C
Relative humidity : 20 to 80%, non condensing
Fusing
Power to the base stations is fused by two replaceable 1.0 AT fuses per base station.
Transport data rate
384 kbit/s
Maximum length base station cable
1.9 km with standard CAT5 cable (FTP CAT5e 4x2x0.5).
General specifications
Length x width : 344 x 195 mm
5.13 Speech Link Unit, SLU – REX-BRD0015 (ROFNB 157 16/1)
Environmental
Temperature
Operating : 0 to 70 °C
Storage : −40 to 70 °C
Relative humidity : 20 to 80%, non condensing
General specifications
Length x width : 344 x 195 mm
Current limitation
Current limitation of the base
stations power : 1.3 A (T = 25 °C)
0.75 A (T = 70 °C)
Transport data rate
Data rate between SLU and