Troubleshooting guide
TD 92735EN
15 May 2012 / Ver. G
Installation and Operation Manual
Unite Connectivity Manager
75
7.7.2 Configuration
The Message Distribution lists for the different interfaces have to be configured to send the
information (i.e. alarms, user data, location etc.) to the Java Server in Unite CM, in order to
give the client access to the information. The address of the Java Server is xxx.xxx.xxx.xxx/
OAJ where “xxx.xxx.xxx.xxx” is the IP address of the Unite CM running the Java Server
application (usually internal host 127.0.0.1).
Refer to 15.2.3 DECT Message Distribution on page 116, 17.4 WLAN Message Distribution
on page 123 and 18.2 System 900 Message Distribution on page 125.
7.8 Importing new OA-XML file
It is possible to import new services, and update existing services, by importing a new OA-
XML file to the Unite CM. The OA-XML description and OA-XML schema documents will also
be updated when a new file is imported.
1 Click “Configuration” on the start page.
2 Select Other > Advanced Configuration in the menu on the Configuration page.
3 Select “OA-XML” in the menu on the Advanced Configuration page. The Import OA-
XML file opens.
4 Click “Browse” and locate the file.
5 Click “Submit File”.
New services are added to the OAP Interface/Java Server list on the System Information
page. The Protocol version in the list shows the currently installed OA-XML version.
7.9 Logging
Logging information can be stored locally, but can also be distributed to other modules or
applications. The System Activity Log can store “activities” such as messages, alarms, faults,
input/output activities, etc. Activity logging is useful for troubleshooting.
1 Click “Configuration” on the start page.
2 Select Other > Advanced Configuration in the menu on the Configuration page.
3 Click “Logging” under Other, in the menu on the Advanced Configuration page.
Figure 38. The Log settings page.
4 Click “Status Log”, “System Activity Log” or “View Advanced parameters”.
• Status Log and System Activity Log specifies the destinations for the logs.
• In View advanced parameters the time for the error relay to release in case of
status log failure, is set. Here it is also possible to enable the Extended Activity
Log, which means that the start of an activity and any action between the start
and stop, are also sent to the Log Viewer.
Figure 34.