Troubleshooting guide

TD 92735EN
15 May 2012 / Ver. G
Installation and Operation Manual
Unite Connectivity Manager
63
2 Enter the secondary module using the virtual IP-address. Note that Secondary is
stated in the upper left corner indicating that this module currently is the active
module.
3 Select Status > Active Faults on the Configuration page. The log shows for example
that the secondary module is active and that the primary module has failed. Other
faults might also be shown.
4 Perform an action to ensure that the active module works properly. For example send
a message to a handset to check if it receives the message.
5 Connect the primary module and check if the secondary module starts to synchronize
with the primary module. A completed synchronization is indicated as follows;
On the secondary module; the Status LED and the Power LED will be steady blue
as long the module acts as an active module.
On the primary module; the Status LED is turned off and the Power LED will still
flash blue as long the module acts as a standby module.
The synchronization status on both modules will be changed to Data in sync when
the data is synchronized.
After the test, it is recommended to switch back to the primary module again. See 4.12.5
Fallback to the Primary Unite CM on page 63.
4.12.4 Restrictions on an Active Secondary Module
A secondary module that has become active, has redistricted functionality as follows:
The secondary module can only be up and running as active module for 30 days without
a repaired primary module connected. Note: If you for example shut down the secondary
module day 10, it can still use the remaining twenty days when it is started again. If the
repaired primary module is not connected within 30 days, the secondary module will
fallback as a standby module.
It is not possible to disable the redundancy
It is not possible to use the Troubleshoot mode
It is not possible to perform a backup restore
It is not possible to add a license
It is not possible to run the Wizard
It is not possible to activate the Demonstration Mode.
4.12.5 Fallback to the Primary Unite CM
When a secondary module has become an active module, it will only switch back to the
primary module if the secondary module failures. It is possible to manually switch back to
the primary module when it is in standby mode after repair.