4.9.2 Action Handler
If more than one Unite CM is used it must be defined which module that shall handle event
assignments. Message indications can also be modified dependent on the priority of the
message.
1 Click “Configuration” on the start page.
2 Select Other > Advanced Configuration in the left menu in the Configuration page.
3 Click “Action Handler” in the menu on the Advanced Configuration page.
General parameters
4ClickEdit.
5 Following general parameters can be set:
6 Click “Activate”.
Priority <-> Indication mapping
1 For each priority (Alarm, High, Normal and Low) the following parameters can be set:
2 Click “Activate”.
Settings Description
Assignment Handler
IP address: Enter the IP address of the Action Handler that shall handle
event assignments.
Identity: A unique name for the Action Handler should be entered
when more than one Unite CM is used.
Individual group
number response: Set toYes if an action sent to an address, that is diverted to
two or more members, shall wait for responses from all
members before deciding the action to be a failure.
Report status: Set to “Yes” if status for all actions sent from the Action
Handler shall be reported back to the Event Handler.
Settings Description
Interval time: Time between indication repetitions
Number of indications: How many times the indication shall be repeated
Reminder, session: Time between indications until message is deleted
Reminder, attention: Time between indications before message is selected
Colour: Colour to be used for the message
Beep code: Type of beep code