Troubleshooting guide
TD 92735EN
15 May 2012 / Ver. G
Installation and Operation Manual
Unite Connectivity Manager
209
Appendix E: Fault Handling Configuration Example
Figure 96. Unite CM fault handling in an IP-DECT system installation.
This example shows a Unite CM connected to an IP-DECT System. A lamp is connected to
Unite CM error relay and Unite CM is configured to activate the error relay and light the lamp
for 60 seconds when a DECT error is reported.
NOTE: If the redundancy functionality is activated (see 4.12 Redundancy on page 59), the
error relay should only be connected to the primary Unite CM since it is preferred to
be the active module.
For extra security, Unite CM is also configured to send an e-mail to a user in the system.
NOTE: Requires an additional license, see 1.1 Licenses for Unite CM on page 1 and that the
mail server IP address has been set in the wizard.
Settings
The actions are set up to trigger when Unite CM detects an error on the connection to the IP-
DECT system. The actions on the triggers are to light a lamp and to send an e-mail.
1 Select Fault Handling > Fault Actions in the menu on the Configuration page.
Figure 87.
Local Area Network
(LAN)
Main PBX
Browser
IP-DECT system
Unite
Connectivity
Manager
IP Gateway
Mail server