Troubleshooting guide

TD 92735EN
15 May 2012 / Ver. G
Installation and Operation Manual
Unite Connectivity Manager
169
Default Action
The Default action is triggered on all faults that have not been processed by any of the
previous actions. In the Default action, it is only possible to set actions since it is
automatically triggered on all remaining faults. The Default action cannot be deleted and is
automatically placed last in the action list.
Add Fault Action
1 Click the “Add Action” button.
2 Enter the name of the action (mandatory) and additional text, if wanted, in the Notes
field.
3 Enter the trigger conditions. The trigger can include either host name, IP address type
of module or level of the fault. The type of module is found in the Unite Module
overview page.
At least one of the three fields Hostname/IP address, Module or Level must be
entered to create a trigger.
4 The action can have more than one trigger. To add more triggers, click “Add Trigger”.
5 Define actions that indicate the fault, see descriptions under Define Actions below,
how to configure the different types of actions.
6 Click “Save”, located at the bottom of the page. The fault action is saved and added
before the default action in the list on the Fault Actions page. By expanding the fault
action, the triggers and actions are shown.
7 If needed, change the priority of the fault action by clicking the arrow symbols on the
right side of the “Edit” button.
8 It is possible to edit a fault action by clicking the “Edit” button.