Troubleshooting guide

TD 92735EN
15 May 2012 / Ver. G
Installation and Operation Manual
Unite Connectivity Manager
164
Changing Monitoring Settings
1 Click “Setup” to set up monitoring parameters.
2 Enter/select following settings:
3 Click “Save”.
Setting Description
Input: The inputs are defined in the I/O setup page. The input can be
changed, for example if the monitored equipment has been
moved. Information about changes can be written in the Notes
field.
Monitoring: If the input should be monitored or not.
When starting to monitor inputs from Unite CM, the status will
always be OK regardless of the actual state of the input. This
give that if the input is active when monitoring is started no
Status Log is sent.
Equipment Name: The name is shown as Module in the Status Log.
Level: The level that the fault shall be reported as.
Persistent: Select the Persistent check box, if a fault should remain until the
input is not active any longer.
Event Description:I Is shown under Description for the Status log.