Troubleshooting guide

TD 92735EN
15 May 2012 / Ver. G
Installation and Operation Manual
Unite Connectivity Manager
161
5 Click “Save”.
23.2 IP Equipment
Unite CM can supervise IP Equipment by sending ICMP ping requests. If the equipment does
not answer on the sent request, a persistent Status Log will be generated. It includes the
configured Equipment name and IP address or host name. The default level is “Error”, but
can be changed on the setup page. The persistent fault will be cleared when the equipment
responds again.
Unite CM can send a supervision request (either to a Unite module or an ICMP ping) every
second, i.e. if the interval is set to 30 seconds up to 30 modules (Unite or IP Equipment) can
be supervised. If this limit is exceeded, the interval will automatically be increased.
Example: if the interval is set to 30 seconds as above, but the modules to supervise are 60,
the interval will be increased to 60 seconds.
When supervision is started/ended and when the supervision interval is changed, an
Activity Log with information about the changes will be sent.
1 Click “Configuration” on the start page.
2 Select Supervision > IP Equipment in the menu on the Configuration page.
Adding IP Equipment
1 Enter IP address or host name.
2 Click “Add IP Equipment” to add equipment to the survey.
Event Description: A customized description that will be added to the Status Log.
Interface Description:
A customized description of the service.
Status Symbols Description
Supervision OK
Equipment lost
Not Supervised