Troubleshooting guide
TD 92735EN
15 May 2012 / Ver. G
Installation and Operation Manual
Unite Connectivity Manager
120
NOTE: Make sure that the phone user and the handset password is the same as in the setup
for the CUCM, and that the SNMP parameters correspond to the SNMP parameters in
the CUCM.
4In the CallManager address text field, enter IP address of the CUCM.
5In the CallManager device list refresh interval (minutes) text field, set the refresh
interval value.
The complete device information is read at regular intervals, default once a day. To
refresh too often in systems with huge amount of devices puts a heavy load for the
CUCM. In large systems it is recommended to increase the interval time for reading
the list of telephone numbers from the CUCM.
6In the SNMP version drop-down list, select SNMP version to use for the
communication with the CUCM.
7 Set the SNMP parameters corresponding to the settings in the CUCM.
The only required parameter for SNMP version 2, is the community name.
• SNMP community, version 2 only
For increased security in SNMP version 3, the following need to be set.
• SNMP privacy (encryption method)
• SNMP privacy password (encryption password)
• SNMP authentication (authentication method)
• SNMP authentication password
• SNMP user name for connecting