Troubleshooting guide

TD 92735EN
15 May 2012 / Ver. G
Installation and Operation Manual
Unite Connectivity Manager
114
5 Continue in A) IP-DECT system with a Single Master or B) IP-DECT system with
Multiple Masters below.
A) IP-DECT system with a Single Master
1 Enter the IP address to the DECT system
2 Enter a secondary IP address if two DECT system are used for redundancy
purposes, enter the IP address to the secondary DECT system in the Secondary
DECT IP Address text field.
B) IP-DECT system with Multiple Masters
Multiple DECT interfaces are used for connections to an IP-DECT multi-master system
with a common PBX number plan.
NOTE: All numbers in the system must be unique, i.e. a number for a user in one system
cannot be the same as a number for a user in another system.
1 If not already set via the wizard, click the Multiple Locations link, select “Yes” and
reboot the module.
2 Select IP-DECT in the menu and click a “NOT USED” link.
3 Enter a name for the DECT interface.
4 Enter the Master IP address.
5 Enter the Standby Master IP address if a secondary Master is used as a backup.
6 Configure desired number of interfaces. Up to 20 DECT interfaces can be set up.
The relative order when entering the IP-DECT Masters makes no difference.
7 If data shall be encrypted for multiple IP-DECT locations, click the Encrypt data link
and select “Yes”.
Every configured connection is supervised every 60 seconds. If the supervision fails the
connection is handled as lost and a persistent fault is generated. After solving a problem
with a lost connection, it can take up to one minute before the connection over the DECT
interface is restored. During that time the connection is considered lost and no messages
will be sent to that specific connection.