Troubleshooting guide
TD 92735EN
15 May 2012 / Ver. G
Installation and Operation Manual
Unite Connectivity Manager
104
5 Click “Activate”.
Display width (characters): Defines number of characters (1 - 100) to be shown
in the text display. Longer messages will be
truncated.
Default: “16”
Message display time: Time for a message to be displayed if there is a new
message in the message queue.
If a time is specified here it overrides the Message
display time specified in general settings. Choose
default if the general setting shall be used.
Default: “Default”
Buzzer options:
NOTE: Only applicable for
teleCARE displays.
Defines how the buzzer operates during display of
messages.
Off - Buzzer is switched off (Default)
New calls only - Buzzer sounds when new call is
displayed.
Every time - Buzzer sounds for every displayed
message.
Every 5th time - Buzzer sounds for every 5th
displayed message.
Display mode:
NOTE: Only applicable for
teleCARE displays.
Defines how messages is displayed.
Scrolling display - The message is scrolled onto the
display from the bottom.
NOTE: When there is only 1 active message the
display will not scroll.
Constant display - The message is shown directly. At
the end of the display time the display is blanked for
300 ms before the next message is shown.
Default: Scrolling.
Buzzer off period:
NOTE: Only applicable for
teleCARE displays.
Specifies the times of the day when a display’s
buzzer will be muted. The Buzzer off period consists
of a start time and an end time written in the
following format: hh:mm-hh:mm (no spaces are
allowed in the text string).
Example:
00:00-00:00; the buzzer is always muted.
Empty field (default); the buzzer is never muted.
NOTE: Do not enter overlapping time periods.
If the field(s) is empty, the corresponding settings
located under General setting will used.