Default display type: The display type selected here will be used as
default display type when adding text displays. This
can be overridden individually for each display.
Empty message: Specifies what will be displayed if no messages are
stored. How to set the current time (12 or 24 hour
clock) as empty message is described in the
helptext.
Message refresh time
(seconds):
NOTE: Only applicable for
Adaptive/NICD displays.
Forces the display to refresh even if the message
has not changed.
Default: “70” (disabled by “0”)
Priority x colour:
(x = priority 1 to 9)
The message priority can be visible in the text
display with different colors (Red, Green, Yellow).
Default: “Red” for priority 1-3, “Yellow” for priority
4-6 and “Green” for priority 7-9
Buzzer off period:
NOTE: Only applicable for
teleCARE displays.
Specifies the times of the day when a display’s
buzzer will be muted. The Buzzer off period consists
of a start time and an end time written in the
following format: hh:mm-hh:mm (no spaces are
allowed in the text string).
Example:
00:00-00:00; the buzzer is always muted.
Empty field (default); the buzzer is never muted.
NOTE: Do not enter overlapping time periods.
These settings are valid for all the defined displays,
but can be overridden individually for each display.
Text Display settings
ID: The identity set here is used as the call number
when messages are sent to this text display
(max 30 characters).
IP address: The display’s IP address.
IP port: The IP port used for communication with the text
display.
Default: “3001”
NOTE: Default port used by teleCARE display is
"2301".
Text display type: Defines the display type of the connected display.
Default: use display type as set under general
settings
Adaptive: for use with Adaptive display.
NICD: for use with Elen display
teleCARE: for use with Elen display (teleCARE)