Troubleshooting guide

TD 92735EN
15 May 2012 / Ver. G
Installation and Operation Manual
Unite Connectivity Manager
100
11.1.4 HTTP client
1 Click a “NOT USED” link and configure following HTTP client parameters
2 Click “Activate”.
11.2 Data Monitor
This is used to monitor data received by the ASCII input.
1 Click “Configuration” on the start page.
2 Select Other > Data Monitor in the menu on the Configuration page.
3 Select Input in the drop-down list.
4 Select “Show raw data” or “Show parsed data”.
5 Click “Get Data”. Information of received data will be shown in the field below.
It is possible make a TCP connection to port 10129 on Unite CM. In real-time you can get the
same data that has been presented on this page by sending some commands on the TCP
connection.
Commands to use:
type [raw | message | all]
type - what type of data to get.
raw - will look on what is coming in to the module.
message - will look at the content of the message.
all - will look in both raw and message.
HTTP Client settings Description
Click on an HTTP client connection to set the parameters, always use the first in the
list. The following parameters can be set up:
Name: Descriptive name for the HTTP server. Only used in the GUI.
User name: Defines the name for authentication. Should correspond to
the user name for the HTTP server.
User password: Defines the password for authentication. Should correspond
to the password for the HTTP server.
Request timeout: The time set here must correspond to the time set in other
Unite modules and the HTTP timeout in Event Handler.
Additional http header: Header that will be added when connecting to the HTTP
server.