Troubleshooting guide
TD 92735EN
15 May 2012 / Ver. G
Installation and Operation Manual
Unite Connectivity Manager
99
11.1.2 UDP
1 Click a “NOT USED” link and configure following UDP parameters:
2 Click “Activate”.
11.1.3 Serial ports
1 Click a “NOT USED” link and configure following Serial port parameters
2 Click “Activate”.
Settings Description
Name: Enter a name for this port
UDP Port: Enter port to receive data on
Character encoding of
external data: Defines how external data shall be interpreted.
Internal data format: Defines how data is formatted when sent to Unite.
Remote IP address:
(1-5)
Specify IP address(es) to accept data from. If left empty all
addresses will be accepted.
Settings Description
Name: Enter a name for this port
Serial port: Select port
Input Start/Stop
character string: Is entered with a syntax code, see 11.1 Syntax for ASCII
Code Translation on page 97.
Input Start/Stop
character string: Is entered with a syntax code, see 11.1 Syntax for ASCII
Code Translation on page 97.
Baud rate: Select baud rate used by the connected module
Data Bits: Select data bits used by the connected module
Stop Bits: Select number of stop bits used by the connected module
Parity: Select parity used by the connected module
RTS: Select how to handle the RTS signal
Restart data capture on
receiving Start Word: Defines if the data capture shall restart when a start
character/word is encountered.
Character encoding of
external data: Defines how external data shall be interpreted.
Internal data format: Defines how data is formatted when sent to Unite.