Troubleshooting guide

TD 92735EN
15 May 2012 / Ver. G
Installation and Operation Manual
Unite Connectivity Manager
98
11.1.1 TCP
1 Click a “NOT USED” link and configure following TCP parameters:
2 Click “Activate”.
Setting Description
Name: Enter a name for this port
TCP Port: Enter port to receive data on
Input Start/Stop
character string:
Is entered with a syntax code, see 11.1 Syntax for ASCII
Code Translation on page 97.
Output Start/Stop
character string:
Is entered with a syntax code, see 11.1 Syntax for ASCII
Code Translation on page 97.
End of Session as
delimiter:
Disabled as default
Restart data capture on
receiving Start Word:
Decides if the data capture shall restart when a start
character/word is encountered.
Maximum Clients: Amount of clients that can be connected at the same time.
Close connections
initiated by this
module:
Decides if the connection shall be closed or stay open until
the server shuts down, after data has been sent. Set to “No”
if a reply is expected.
Responses to unknown
connection:
Decides what to do when replying to no longer existing
connections. “Create new” will use the supplied IP address
and port. “Use existing” will use an existing connection to
that IP address and port. If no such connection exists a new
connection will be created.
Character encoding of
external data:
Defines how external data shall be interpreted.
Internal data format: Defines how data is formatted when sent to Unite.
Message to Unite when
new connection is
established:
The message defined here is sent before any data is received
on the new connection.
Message to Unite when
connection is
disconnected:
The message defined here is sent after all other data has
been sent.
Message from Unite to
disconnect connection:
When the message defined here is received it will close the
connection.